Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 461061

Long QT interval – Implantable cardioverter defibrillator in infant – case report


Malčić, Ivan; Buljević, Bruno; Kniewald, Hrvoje; Šarić, Dalibor; Ugljen, Ranko; Ferek-Petrić, Božidar; Novak, Milivoj
Long QT interval – Implantable cardioverter defibrillator in infant – case report // 5th World of Paediatric and Cardiac Surgery, Cairns, Australia, 2009
Cairns, Australija, 2009. (poster, nije recenziran, sažetak, ostalo)


CROSBI ID: 461061 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Long QT interval – Implantable cardioverter defibrillator in infant – case report

Autori
Malčić, Ivan ; Buljević, Bruno ; Kniewald, Hrvoje ; Šarić, Dalibor ; Ugljen, Ranko ; Ferek-Petrić, Božidar ; Novak, Milivoj

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, ostalo

Skup
5th World of Paediatric and Cardiac Surgery, Cairns, Australia, 2009

Mjesto i datum
Cairns, Australija, 21.06.2009. - 26.06.2009

Vrsta sudjelovanja
Poster

Vrsta recenzije
Nije recenziran

Ključne riječi
Long QT interval syndrome (LQTS); infant; implantable cardioverter defibrillator

Sažetak
Introduction: Long QT interval syndrome (LQTS) is caused by an abnormality of the hearts’ electrical system although the mechanical function of the heart is basically normal. Electric problems occur because of the pathological changes on the level of cellular ionic canals. Case study: S.L. was admitted in the age of 5 months after cardiac arrest and successful resuscitation. She was resuscitated again in our institution. Ventricular tachycardia patterns which concur with TdP was registered. She had previously been treated with beta-blocators for 2 months. Rhythm normalized after an intravenous application of magnesium sulphates. We started with mexiletine and MgSO4 for 3 months but still had several of ventricular tachycardia crises of the TdP type with loss of conscience. ECG revealed LQTS as definite diagnosis (QTc was 0.54 sec). She had continously been monitored before the implantable cardioverter defibrillator was implanted (ICD) En TrustTM D 154 VCR Eurin Eucomed with epicardial electrodes transvenous SCV 6397 – 58 with a «dual chamber pacing». ICD was implanted subcutaneously in the left abdomen area and is well tolerated. This is the first infant with an ICD implanted in this way in infant age. Genetic analysis of the 10 known genes which cause LQTS interval was negative. Conclusion: Case study presents an infant with a Long QT interval syndrome and threatening TdP incidents with lethal outcome, who had an ICD with epicardial electrodes subcutaneouslly implanted. This seems to be the youngest child with an ICD implanted in this way.

Izvorni jezik
Engleski



POVEZANOST RADA


Projekti:
108-0000000-0125 - Fetalna kardiološka služba u zaštiti perinatalnog mortaliteta i morbiditeta (Malčić, Ivan, MZOS ) ( CroRIS)

Ustanove:
Medicinski fakultet, Zagreb

Profili:

Avatar Url Bruno Buljević (autor)

Avatar Url Ivan Malčić (autor)

Avatar Url Ranko Ugljen (autor)


Citiraj ovu publikaciju:

Malčić, Ivan; Buljević, Bruno; Kniewald, Hrvoje; Šarić, Dalibor; Ugljen, Ranko; Ferek-Petrić, Božidar; Novak, Milivoj
Long QT interval – Implantable cardioverter defibrillator in infant – case report // 5th World of Paediatric and Cardiac Surgery, Cairns, Australia, 2009
Cairns, Australija, 2009. (poster, nije recenziran, sažetak, ostalo)
Malčić, I., Buljević, B., Kniewald, H., Šarić, D., Ugljen, R., Ferek-Petrić, B. & Novak, M. (2009) Long QT interval – Implantable cardioverter defibrillator in infant – case report. U: 5th World of Paediatric and Cardiac Surgery, Cairns, Australia, 2009.
@article{article, author = {Mal\v{c}i\'{c}, Ivan and Buljevi\'{c}, Bruno and Kniewald, Hrvoje and \v{S}ari\'{c}, Dalibor and Ugljen, Ranko and Ferek-Petri\'{c}, Bo\v{z}idar and Novak, Milivoj}, year = {2009}, keywords = {Long QT interval syndrome (LQTS), infant, implantable cardioverter defibrillator}, title = {Long QT interval – Implantable cardioverter defibrillator in infant – case report}, keyword = {Long QT interval syndrome (LQTS), infant, implantable cardioverter defibrillator}, publisherplace = {Cairns, Australija} }
@article{article, author = {Mal\v{c}i\'{c}, Ivan and Buljevi\'{c}, Bruno and Kniewald, Hrvoje and \v{S}ari\'{c}, Dalibor and Ugljen, Ranko and Ferek-Petri\'{c}, Bo\v{z}idar and Novak, Milivoj}, year = {2009}, keywords = {Long QT interval syndrome (LQTS), infant, implantable cardioverter defibrillator}, title = {Long QT interval – Implantable cardioverter defibrillator in infant – case report}, keyword = {Long QT interval syndrome (LQTS), infant, implantable cardioverter defibrillator}, publisherplace = {Cairns, Australija} }




Contrast
Increase Font
Decrease Font
Dyslexic Font