Pregled bibliografske jedinice broj: 443884
A novel detection approach based on coupled redox-complexation reaction with 2, 4, 6-Trypyridyl-s-triazine (TPTZ) as an chromogenic reagent and its application to flow-injection spectrophotometric determination of tiopronin {;N-(2-Mercaptopropionyl)-Glycine};
A novel detection approach based on coupled redox-complexation reaction with 2, 4, 6-Trypyridyl-s-triazine (TPTZ) as an chromogenic reagent and its application to flow-injection spectrophotometric determination of tiopronin {;N-(2-Mercaptopropionyl)-Glycine}; // Euroanalysis 2009, Abstracts / Buchberger, Wolfgang ; Lindner, Wolfgang (ur.).
Innsbruck: asac, 2009. str. 749-749 (poster, međunarodna recenzija, sažetak, znanstveni)
CROSBI ID: 443884 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
A novel detection approach based on coupled redox-complexation reaction with 2, 4, 6-Trypyridyl-s-triazine (TPTZ) as an chromogenic reagent and its application to flow-injection spectrophotometric determination of tiopronin {;N-(2-Mercaptopropionyl)-Glycine};
Autori
Kukoč Modun, Lea ; Radić, Njegomir
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
Euroanalysis 2009, Abstracts
/ Buchberger, Wolfgang ; Lindner, Wolfgang - Innsbruck : Asac, 2009, 749-749
Skup
Euroanalysis 2009
Mjesto i datum
Innsbruck, Austrija, 04.09.2009. - 09.09.2009
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
tiopronin; N-(2-Mercaptopropionyl)-Glycine; Flow-injection spectrophotometry; pharmaceuticals
Sažetak
A flow injection spectrophotometric procedure for N-(2–mercaptopropionyl)-glycine (MPG) determination is proposed. The determination is based on coupled redox-complexation reaction between MPG, Fe(III) and 2, 4, 6-Trypyridyl-s-triazine (TPTZ). Firstly MPG reduces Fe(III) to Fe(II) and the reduced Fe(II) is rapidly converted to the highly stable, deep-blue colored Fe(TPTZ)22+. This colored complex was monitored at 593 nm. Optimal conditions for determining MPG are achieved by univariate method. A linear calibration curve is established in a concentration range of 4.0 10-6 to 2.0 10-4 mol L-1 MPG with regression equation y = 4704 x - 0.019 (R2 = 0.9998) (n = 10) and detection limit of 2.35 10-7. The analytical frequency was 60 h-1. The proposed method is simple, rapid, sensitive and reproducible (RSD 0.5%, n = 10), and can be applied for determination of MPG in pharmaceutical preparations up to nanomole quantity. Usual excipients used as additives in pharmaceuticals do not interfere with the proposed method.
Izvorni jezik
Engleski
Znanstvena područja
Kemija
POVEZANOST RADA
Projekti:
011-0000000-3217 - Određivanje tiola primjenom potenciometrijskih senzora i spektroskopije (Radić, Njegomir, MZOS ) ( CroRIS)
125-2120898-3148 - Hrvatsko nazivlje u analitičkoj kemiji (Kaštelan-Macan, Marija, MZOS ) ( CroRIS)
Ustanove:
Kemijsko-tehnološki fakultet, Split,
Fakultet kemijskog inženjerstva i tehnologije, Zagreb