Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 439672

Accuracy of three different apex locators: A clinical study


Simeon, Paris; Ljubičić, Anita; Jukić Krmek, Silvana; Prpić Mehičić, Goranka; Katanec, Davor; Njemirovskij, Vera
Accuracy of three different apex locators: A clinical study // International Endodontic Journal / Dummer, PMH (ur.).
Edinburgh: European Society of Endodontology, 2009. str. 1148-1148 (poster, međunarodna recenzija, sažetak, znanstveni)


CROSBI ID: 439672 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Accuracy of three different apex locators: A clinical study

Autori
Simeon, Paris ; Ljubičić, Anita ; Jukić Krmek, Silvana ; Prpić Mehičić, Goranka ; Katanec, Davor ; Njemirovskij, Vera

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni

Izvornik
International Endodontic Journal / Dummer, PMH - Edinburgh : European Society of Endodontology, 2009, 1148-1148

Skup
14th bienial congres of European Socity of Endodontics

Mjesto i datum
Edinburgh, Ujedinjeno Kraljevstvo, 24.09.2009. - 26.09.2009

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
root canal length; electronic apex locators; pulpitic; apical periodontitis; necrosis

Sažetak
Aim: To compare the accuracy of three different electronic apex locators (EALs) in patients treated for three different endodontic diagnoses. Methodology: Research was performed on 418 endodontic patients, aged 20-58. Initially, each tooth was diagnosed for pulpitis (P), being necrotic without (N) or necrotic with (AP) periapical pathosis, respectively. Working length (WL) was randomly determined with three EALs: ES-02 and ES-03 (Artonic, Zagreb, Croatia) and ProPex (Maillefer, Ballaigues, Switzerland). A total of 794 roots was analysed (245 roots P, 323 roots N, 126 roots AP). Following root filling the distance between the radiological apex and the end of the root-filling was assessed radiographically. Those roots where the fillings ended within 1.5 mm from the radiological apex were deemed as having an accurate WL. The data was statistically analyzed and non-parametric Kruskal-Wallis and Mann-Whitney were used as a post-hoc test. Results: Kruskal-Wallis tests showed that all three EALs were, regardless of make or technical principle, equally accurate in all three diagnoses. They showed no differences in roots with P (χ2 = 2.18 ; df = 2 ; p > 0.05), neither in roots with N (χ2 = 0.63 ; df = 2 ; p > 0.05), nor in roots with AP (χ2 = 3.62 ; df = 2 ; p > 0.05). However, diagnosis-related, Mann-Whitney tests showed that inaccurate WLs were significantly more frequent in roots with AP than in roots with N (Z = 6.47 ; p < 0.05) and roots with P (Z = 8.60 ; p < 0.05) ; inaccurate WLs were more frequent in roots with N than in roots with P (Z = 3.30 ; p < 0.05), for all three EALs. Conclusions: Regardless of make or technical principle, all three EALs are equally accurate ; however, in relation to different diagnoses, they uniformly demonstrated the same degree of discrepancy.

Izvorni jezik
Engleski

Znanstvena područja
Dentalna medicina



POVEZANOST RADA


Projekti:
065-0650445-0434 - Epidemiološki aspekti endodoncije u Republici Hrvatskoj (Krmek, Silvana, MZOS ) ( CroRIS)
065-0650446-0435 - Istraživanje keramičkih materijala i alergija u stomatološkoj protetici (Mehulić, Ketij, MZOS ) ( CroRIS)

Ustanove:
Stomatološki fakultet, Zagreb


Citiraj ovu publikaciju:

Simeon, Paris; Ljubičić, Anita; Jukić Krmek, Silvana; Prpić Mehičić, Goranka; Katanec, Davor; Njemirovskij, Vera
Accuracy of three different apex locators: A clinical study // International Endodontic Journal / Dummer, PMH (ur.).
Edinburgh: European Society of Endodontology, 2009. str. 1148-1148 (poster, međunarodna recenzija, sažetak, znanstveni)
Simeon, P., Ljubičić, A., Jukić Krmek, S., Prpić Mehičić, G., Katanec, D. & Njemirovskij, V. (2009) Accuracy of three different apex locators: A clinical study. U: Dummer, P. (ur.)International Endodontic Journal.
@article{article, author = {Simeon, Paris and Ljubi\v{c}i\'{c}, Anita and Juki\'{c} Krmek, Silvana and Prpi\'{c} Mehi\v{c}i\'{c}, Goranka and Katanec, Davor and Njemirovskij, Vera}, editor = {Dummer, P.}, year = {2009}, pages = {1148-1148}, keywords = {root canal length, electronic apex locators, pulpitic, apical periodontitis, necrosis}, title = {Accuracy of three different apex locators: A clinical study}, keyword = {root canal length, electronic apex locators, pulpitic, apical periodontitis, necrosis}, publisher = {European Society of Endodontology}, publisherplace = {Edinburgh, Ujedinjeno Kraljevstvo} }
@article{article, author = {Simeon, Paris and Ljubi\v{c}i\'{c}, Anita and Juki\'{c} Krmek, Silvana and Prpi\'{c} Mehi\v{c}i\'{c}, Goranka and Katanec, Davor and Njemirovskij, Vera}, editor = {Dummer, P.}, year = {2009}, pages = {1148-1148}, keywords = {root canal length, electronic apex locators, pulpitic, apical periodontitis, necrosis}, title = {Accuracy of three different apex locators: A clinical study}, keyword = {root canal length, electronic apex locators, pulpitic, apical periodontitis, necrosis}, publisher = {European Society of Endodontology}, publisherplace = {Edinburgh, Ujedinjeno Kraljevstvo} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE





Contrast
Increase Font
Decrease Font
Dyslexic Font