Pregled bibliografske jedinice broj: 434749
Dynamic testing of marine sediments at the Pelješac bridge site
Dynamic testing of marine sediments at the Pelješac bridge site // Proceedings of the 17th International Conference on Soil Mechanics and Geotechnical Engineering, The Academia & Practice of Geotechnical Engineering / Hamza, M., Shahien, M., El-Mossallamy, Yasser. (ur.).
Alexandria: IOS Press, 2009. str. 344-347 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 434749 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Dynamic testing of marine sediments at the Pelješac bridge site
Autori
Ivšić, Tomislav ; Vrkljan, Ivan ; Zlatović, Sonja ; Mavar, Ramon
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of the 17th International Conference on Soil Mechanics and Geotechnical Engineering, The Academia & Practice of Geotechnical Engineering
/ Hamza, M., Shahien, M., El-Mossallamy, Yasser. - Alexandria : IOS Press, 2009, 344-347
ISBN
978-1-60750-031-5
Skup
17th International Conference on Soil Mechanics and Geotechnical Engineering, The Academia & Practice of Geotechnical Engineering
Mjesto i datum
Aleksandrija, Egipat, 05.10.2009. - 09.10.2009
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
geotechnical investigation; dynamic soil testing; marine sediments
Sažetak
The complex geotechnical investigations were performed at the location of the long bridge at the south Adriatic. The sea depth at the location is 27 to 28m. Marine sediments, deposited in horizontal layers, are very soft to soft high plasticity clay with silt, from the sea bottom to the depth of 60m where overconsolidated clay with fragments of lime and shells was found. The depth of base lime rock varies along the bridge from the surface at the coasts to 100m under the sea bottom. Seismicity of the location is significant. Comprehensive dynamic testing was performed in order to establish the representative seismic soil profile. Vane shear, SCPT and CPTU testing (seismic cone penetrometer and piezocone) were performed to the depth of 25m, as well as down hole testing to the depth of 80m. Numerous classification tests, compressibility and strength tests were performed in the laboratory. Undisturbed specimens from the borehole for down hole measurements were tested in the resonant column apparatus, double specimen direct simple shear device (DSDSS), and in the triaxial apparatus with bender elements. Effects of mean effective stress and excitation characteristics are investigated in all tests. The compilation of basic investigation results is presented. Values of shear modulus obtained from all the laboratory tests and from wave velocity measurements are compared taking into account shear deformation which varies from 0, 00003% in resonant column tests to 3%, showing very good agreement.
Izvorni jezik
Engleski
Znanstvena područja
Građevinarstvo
POVEZANOST RADA
Projekti:
149-0831529-3050 - MEHANIČKA STABILNOST I FUNKCIONALNOST ODLAGALIŠTA KOMUNALNOG OTPADA
082-0822161-2187 - Ispitivanje i modeliranje poboljšanog tla i stijene (Kovačević, Meho-Saša, MZOS ) ( CroRIS)
110-0831529-1517 - Ispitivanje mehaničkih svojstava bentonitnih tepiha u brtvenim barijerama (Vrkljan, Ivan, MZOS ) ( CroRIS)
Ustanove:
Građevinski fakultet, Zagreb,
INSTITUT IGH, d.d.,
Tehničko veleučilište u Zagrebu