Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 430773

Regional Inter-comparative ADCP Discharge Measurement


Terek, Borivoj
Regional Inter-comparative ADCP Discharge Measurement // ADCPs in Action 2009 Users’ Conference
San Diego (CA): Teledyne RD Instruments, 2009. (predavanje, nije recenziran, sažetak, stručni)


CROSBI ID: 430773 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Regional Inter-comparative ADCP Discharge Measurement

Autori
Terek, Borivoj

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, stručni

Izvornik
ADCPs in Action 2009 Users’ Conference / - San Diego (CA) : Teledyne RD Instruments, 2009

Skup
ADCPs in Action 2009 Users’ Conference

Mjesto i datum
San Diego (CA), Sjedinjene Američke Države, 05.10.2009. - 07.10.2009

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Nije recenziran

Ključne riječi
ADCP; international inter-comparative measurements; discharge; Agila software
(ADCP; međunarodno interkomparacijsko mjerenje; protok; Agila software)

Sažetak
Inter-comparative ADCP discharge measurements, as well as the analysis of the measurement results, which took place in Sisak, on Sava river during September 2008, are presented in the paper. The measurements were carried out by eleven measuring teams form Austria, Slovenia, Serbia, Hungary and Croatia, having sixteen measuring ADCP units at disposal in total. In order to evaluate the quality of the inter-comparative measurements, beside the most important measured value, the discharge, some other measuring parameters such as geometrical parameters of the river bed, mean direction of flow, internal compass performance etc. are analyzed and presented in the paper as well. The measurements were carried out successfully with fourteen ADCP units. The results of the discharge measurements are mutually in accordance and highly compatible. The discrepancies of the discharge measurements do not exceed 2.5 % margin. In addition, the results of the post-processing analysis show those discrepancies are most likely due to unappropriate measuring procedure, rather then instrument failure. There were three measurements of such type recorded, all of them discussed in the paper. Analysis of the measurements data was performed using Teledyne RD Instruments WinRiver software package as well as Agila software, the later have been issued by The German Federal Institute of Hydrology (Bundesanstalt für Gewässerkunde, Koblenz).

Izvorni jezik
Engleski

Znanstvena područja
Temeljne tehničke znanosti



POVEZANOST RADA


Ustanove:
Državni hidrometeorološki zavod

Profili:

Avatar Url Borivoj Terek (autor)


Citiraj ovu publikaciju:

Terek, Borivoj
Regional Inter-comparative ADCP Discharge Measurement // ADCPs in Action 2009 Users’ Conference
San Diego (CA): Teledyne RD Instruments, 2009. (predavanje, nije recenziran, sažetak, stručni)
Terek, B. (2009) Regional Inter-comparative ADCP Discharge Measurement. U: ADCPs in Action 2009 Users’ Conference.
@article{article, author = {Terek, Borivoj}, year = {2009}, keywords = {ADCP, international inter-comparative measurements, discharge, Agila software}, title = {Regional Inter-comparative ADCP Discharge Measurement}, keyword = {ADCP, international inter-comparative measurements, discharge, Agila software}, publisher = {Teledyne RD Instruments}, publisherplace = {San Diego (CA), Sjedinjene Ameri\v{c}ke Dr\v{z}ave} }
@article{article, author = {Terek, Borivoj}, year = {2009}, keywords = {ADCP, me\djunarodno interkomparacijsko mjerenje, protok, Agila software}, title = {Regional Inter-comparative ADCP Discharge Measurement}, keyword = {ADCP, me\djunarodno interkomparacijsko mjerenje, protok, Agila software}, publisher = {Teledyne RD Instruments}, publisherplace = {San Diego (CA), Sjedinjene Ameri\v{c}ke Dr\v{z}ave} }




Contrast
Increase Font
Decrease Font
Dyslexic Font