Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 42096

Double tiering as an option for spent fuel pool capacity increase


Baće, Mile; Trontl, Krešimir; Šmuc, Tomislav
Double tiering as an option for spent fuel pool capacity increase // Proceedings of the International Conference Nuclear Energy in Central Europe 2000 / Ravnik, Matjaž ; Žagar, Tomaž (ur.).
Ljubljana: NSS, 2000. str. 105.1-105.8 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 42096 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Double tiering as an option for spent fuel pool capacity increase

Autori
Baće, Mile ; Trontl, Krešimir ; Šmuc, Tomislav

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Proceedings of the International Conference Nuclear Energy in Central Europe 2000 / Ravnik, Matjaž ; Žagar, Tomaž - Ljubljana : NSS, 2000, 105.1-105.8

Skup
International Conference Nuclear Energy in Central Europe 2000

Mjesto i datum
Bled, Slovenija, 11.09.2000. - 14.09.2000

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
spent fuel pool; increase capacity; double tiering; criticality analysis; shielding analysis

Sažetak
Using the SCALE-4 code package we have analyzed double tiering as an option of the NPP Krško spent fuel pool capacity increase. Both, criticality of the spent fuel pool expressed through multiplication factor value, as well as the gamma and neutron dose rates in the vicinity of the spent fuel pool have been calculated and compared to the values of the existing spent fuel pool. Dose rates are also compared to dose limit in 10 CFR 20 for the restricted work area, and effective multiplication factor is compared to ANSI/ANS 57.2-1983 demand. Our analyses showed that from the criticality and dose rate standpoint, double tiering is an open option for NPP Krško spent fuel pool capacity increase. However, final decision on the effectiveness of the capacity increase method, can not be given without detailed thermal-hydraulic, static, economic and seismic analyses.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Projekti:
00980501

Ustanove:
Institut "Ruđer Bošković", Zagreb

Profili:

Avatar Url Mile Baće (autor)

Avatar Url Krešimir Trontl (autor)

Avatar Url Tomislav Šmuc (autor)


Citiraj ovu publikaciju:

Baće, Mile; Trontl, Krešimir; Šmuc, Tomislav
Double tiering as an option for spent fuel pool capacity increase // Proceedings of the International Conference Nuclear Energy in Central Europe 2000 / Ravnik, Matjaž ; Žagar, Tomaž (ur.).
Ljubljana: NSS, 2000. str. 105.1-105.8 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Baće, M., Trontl, K. & Šmuc, T. (2000) Double tiering as an option for spent fuel pool capacity increase. U: Ravnik, M. & Žagar, T. (ur.)Proceedings of the International Conference Nuclear Energy in Central Europe 2000.
@article{article, author = {Ba\'{c}e, Mile and Trontl, Kre\v{s}imir and \v{S}muc, Tomislav}, year = {2000}, pages = {105.1-105.8}, keywords = {spent fuel pool, increase capacity, double tiering, criticality analysis, shielding analysis}, title = {Double tiering as an option for spent fuel pool capacity increase}, keyword = {spent fuel pool, increase capacity, double tiering, criticality analysis, shielding analysis}, publisher = {NSS}, publisherplace = {Bled, Slovenija} }
@article{article, author = {Ba\'{c}e, Mile and Trontl, Kre\v{s}imir and \v{S}muc, Tomislav}, year = {2000}, pages = {105.1-105.8}, keywords = {spent fuel pool, increase capacity, double tiering, criticality analysis, shielding analysis}, title = {Double tiering as an option for spent fuel pool capacity increase}, keyword = {spent fuel pool, increase capacity, double tiering, criticality analysis, shielding analysis}, publisher = {NSS}, publisherplace = {Bled, Slovenija} }




Contrast
Increase Font
Decrease Font
Dyslexic Font