Pregled bibliografske jedinice broj: 410974
Novel high sensitive potentiometric sensor for ethoxylated nonionic surfactants
Novel high sensitive potentiometric sensor for ethoxylated nonionic surfactants // XXI. Hrvatski skup kemičara i kemijskih inženjera, Knjiga sažetaka / Pičuljan, Katarina ; Smolec, Sonja (ur.).
Zagreb: Hrvatsko društvo kemijskih inženjera i tehnologa (HDKI), 2009. str. 177-177 (poster, domaća recenzija, sažetak, znanstveni)
CROSBI ID: 410974 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Novel high sensitive potentiometric sensor for ethoxylated nonionic surfactants
Autori
Sak-Bosnar, Milan ; Sakač, Nikola ; Galović, Olivera ; Samardžić, Mirela ; Madunić-Čačić, Dubravka ; Grabarić, Zorana
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
XXI. Hrvatski skup kemičara i kemijskih inženjera, Knjiga sažetaka
/ Pičuljan, Katarina ; Smolec, Sonja - Zagreb : Hrvatsko društvo kemijskih inženjera i tehnologa (HDKI), 2009, 177-177
ISBN
987-953-6894-38-3
Skup
XXI. Hrvatski skup kemičara i kemijskih inženjera
Mjesto i datum
Trogir, Hrvatska, 19.04.2009. - 22.04.2009
Vrsta sudjelovanja
Poster
Vrsta recenzije
Domaća recenzija
Ključne riječi
Potentiometric sensor; ethoxylated nonionic surfactants
Sažetak
Ethoxylated nonionic surfactants (EONS) form complexes with a variety of monovalent and divalent cations, alkaline earth metals and transition metals. Most of the analytical methods for determinating the presence of polyethoxylated nonionic surfactants are based on the formation of tetraphenylborate (TPB) salts of pseudocationic complexes of nonionics surfactants with some metal cations. A new sensitive nonionic surfactant sensor has been prepared, based on 1, 3-didecyl-2-methyl-imidazolium-tetraphenylborate ion-exchange complex as a sensing material incorporated into PVC-membrane plasticized with o-NPOE. The sensor exhibited positive linear non-Nernstian response toward different nonionic surfactants and Nernstian response toward tetraphenylborate in barium chloride solution. It has been used as an end-point indicator for potentiometric titration of analytical and technical grade polyethoxylated nonionic surfactants. The interfering effect of some alkaline, alkaline earth, and heavy metal cations, has been demonstrated by displaying their calibration curves compared with that of Triton X-100. The sensor has been applied to the study of the reaction stoichiometry of barium and Triton X-100 pseudoionic complex formation and its reaction with tetraphenylborate. The mechanism of complexing, at a fixed Ba2+ concentration, has been proposed for Triton X-100 concentrations above the stoichiometric concentration. It was also evidenced that the concentration of the formed pseudoionic complex increased with an increase in Ba2+ concentration, at a fixed Triton X-100 concentration, even after the consumption of Triton X-100 as the limiting reactant. These results suggest that the standardization of sodium tetraphenylborate and the determination of polyethoxylated nonionic surfactants (EONS) in real samples must be performed at a specified Ba2+ concentration for each particular EONS investigated.
Izvorni jezik
Engleski
Znanstvena područja
Kemija
POVEZANOST RADA
Projekti:
058-0580000-3071 - Razvoj kemometričkih i senzorskih metoda određivanja različitih analita (Ninčević Grassino, Antonela, MZOS ) ( CroRIS)
291-0580000-0169 - Kemijski senzori za primjenu u biomedicini, hrani i zaštiti okoliša (Sak-Bosnar, Milan, MZOS ) ( CroRIS)
Ustanove:
Prehrambeno-biotehnološki fakultet, Zagreb,
Sveučilište u Osijeku - Odjel za kemiju
Profili:
Dubravka Madunić-Čačić
(autor)
Zorana Grabarić
(autor)
Nikola Sakač
(autor)
Mirela Samardžić
(autor)
Olivera Galović
(autor)
Milan Sak-Bosnar
(autor)