Pregled bibliografske jedinice broj: 40968
Influence of Turbogenerator Set Parameters on the Calculation of Shaft Transient Torsional Strains
Influence of Turbogenerator Set Parameters on the Calculation of Shaft Transient Torsional Strains // MELECON 96 Industrial Applications in Power Systems, Computer Science and Telecommunications / De Sario, Marco ; Maione, Bruno ; Pugliese, Pasquale ; Savino, M. (ur.).
Bari: Grafiche Colucci - Monopoli - Bari, 1996. str. 309-312 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 40968 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Influence of Turbogenerator Set Parameters on the Calculation of Shaft Transient Torsional Strains
Autori
Maljković, Zlatko ; Kuterovac, Ljiljana ; Gašparac, Ivan
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
MELECON 96 Industrial Applications in Power Systems, Computer Science and Telecommunications
/ De Sario, Marco ; Maione, Bruno ; Pugliese, Pasquale ; Savino, M. - Bari : Grafiche Colucci - Monopoli - Bari, 1996, 309-312
Skup
MELECON 96, 8th Mediterranian Electrotechnical Conference, Industrial Applications in Power Systems, Computer Science and Telecommunications
Mjesto i datum
Bari, Italija, 13.05.1996. - 16.05.1996
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
turbogenerator; torsional strains; shaft; parameter
Sažetak
The paper involves an analysis of the impact of some turbogenerator set parameters which con-siderably influence its mechanical behaviour on the calculations of torsional strains. The analysis is carried out for a case of a three-phase short circuit at one of two parallel lines through which a generator is supplied followed by a fault clearing. Maximum torsional torques and critical fault clearing times at which they occur are presented. The mechanical parameters which have the largest influence on the tor-sional strains in the shaft are the stiffness coefficients of the shaft sections and the mechanical time constants (or moments of inertia) of the generator and the turbine rotors. The influence of mechanical damping coefficients is less significant. Maximum torsional torques are also indirectly influen-ced by electrical parameters of the generator, primarily by the subtran-sient and the transient synchronous reac-tance, but their impact is minor. Cal-culated time responses of torsional torques for the combined fault show that inaccurately defined mechanical parameters can lead to wrong conclusions concer-ning maximum values of torsional torques which could occur during a fault.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika