Pregled bibliografske jedinice broj: 40958
The improvement of accuracy in 3D motion reconstruction systems
The improvement of accuracy in 3D motion reconstruction systems // Proceedings of the European Medical & Biological Engineering Conference EMBEC '99 / Rehak, Peter ; Hutten, Helmut (ur.).
Beč: Peter Peregrinus Ltd., 1999. str. 832-833 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 40958 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
The improvement of accuracy in 3D motion reconstruction systems
Autori
Pribanić, Tomislav ; Cifrek, Mario ; Tonković, Stanko
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of the European Medical & Biological Engineering Conference EMBEC '99
/ Rehak, Peter ; Hutten, Helmut - Beč : Peter Peregrinus Ltd., 1999, 832-833
Skup
EMBEC '99 - European Medical and Biological Engineering Conference
Mjesto i datum
Beč, Austrija, 04.11.1999. - 07.11.1999
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
3D reconstruction accuracy; direct linear transformation; calibration points
Sažetak
This paper deals with residual of over-determined system after the calculation of direct linear transformation (DLT) parameters, its possible reduction and impact on overall reconstruction ac-curacy. A method for improvement of reconstruction accuracy based on selection of calibration points is presented. It will be shown that taking only those calibration points that do not significantly increase the over-all residual of the over-determined system improve the accuracy and decreases the number of calibration points needed.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika