Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 407880

CALIBRATION OF LINE SCALES AT LFSB


Medić, Srđan; Mudronja, Vedran; Runje, Biserka
CALIBRATION OF LINE SCALES AT LFSB // Proceedings 1 st Regional Metrology Organisations Symposium – RMO 2008 ; 20th International Metrology Symposium
Cavtat, 2008. (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 407880 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
CALIBRATION OF LINE SCALES AT LFSB

Autori
Medić, Srđan ; Mudronja, Vedran ; Runje, Biserka

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Proceedings 1 st Regional Metrology Organisations Symposium – RMO 2008 ; 20th International Metrology Symposium / - Cavtat, 2008

Skup
Proceedings 1 st Regional Metrology Organisations Symposium – RMO 2008 ; 20th International Metrology Symposium

Mjesto i datum
Dubrovnik, Hrvatska; Cavtat, Hrvatska, 12.11.2008. - 15.11.2008

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
length; calibration; line scale

Sažetak
Calibration of the line scales at the level of measurement uncertainties of the order of value U=0, 1μ m, k=2 represents today still a world problem, although these levels of measurement uncertainties are necessary in the context of ensuring the traceability. The greatest drawback of the measurement methods for the calibration of the line scales is the influence (subjectivity) of the measurer in the procedure of sighting the line scale, regardless of the use of technical aids (microscope, cameras, etc.). So, the Laboratory for precise measurement of length (LFSB) at Faculty of Mechanical Engineering and Naval Architecture in Zagreb started to design their own optoelectronic system for the calibration of line scales. The paper presents main characteristics of the device for calibration of line scales, software for sighting of lines, influences on measurement uncertainties and our measuring results of calibration NPL line scale which is also calibrated at PTB. Special attention in the paper will be given in a study of the scale and laser measuring system alignment. Also, the paper presents influences of the pitch and yaw errors of the table and the elastic table deformations on the calibration results.

Izvorni jezik
Engleski

Znanstvena područja
Strojarstvo



POVEZANOST RADA


Projekti:
120-1201785-1784 - Nacionalni laboratorij za duljinu (Mudronja, Vedran, MZOS ) ( CroRIS)

Ustanove:
Fakultet strojarstva i brodogradnje, Zagreb

Profili:

Avatar Url Srđan Medić (autor)

Avatar Url Vedran Mudronja (autor)

Avatar Url Biserka Runje (autor)


Citiraj ovu publikaciju:

Medić, Srđan; Mudronja, Vedran; Runje, Biserka
CALIBRATION OF LINE SCALES AT LFSB // Proceedings 1 st Regional Metrology Organisations Symposium – RMO 2008 ; 20th International Metrology Symposium
Cavtat, 2008. (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Medić, S., Mudronja, V. & Runje, B. (2008) CALIBRATION OF LINE SCALES AT LFSB. U: Proceedings 1 st Regional Metrology Organisations Symposium – RMO 2008 ; 20th International Metrology Symposium.
@article{article, author = {Medi\'{c}, Sr\djan and Mudronja, Vedran and Runje, Biserka}, year = {2008}, keywords = {length, calibration, line scale}, title = {CALIBRATION OF LINE SCALES AT LFSB}, keyword = {length, calibration, line scale}, publisherplace = {Dubrovnik, Hrvatska; Cavtat, Hrvatska} }
@article{article, author = {Medi\'{c}, Sr\djan and Mudronja, Vedran and Runje, Biserka}, year = {2008}, keywords = {length, calibration, line scale}, title = {CALIBRATION OF LINE SCALES AT LFSB}, keyword = {length, calibration, line scale}, publisherplace = {Dubrovnik, Hrvatska; Cavtat, Hrvatska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font