Pregled bibliografske jedinice broj: 406447
Computer Vision System for Human Anthropometric Parameters Estimation
Computer Vision System for Human Anthropometric Parameters Estimation // WSEAS transactions on systems, 8 (2009), 3; 430-439 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 406447 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Computer Vision System for Human Anthropometric Parameters Estimation
Autori
Stančić, Ivo ; Šupuk, Tamara ; Cecić, Mojmil
Izvornik
WSEAS transactions on systems (1109-2777) 8
(2009), 3;
430-439
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
biomechanics ; human anthropometry ; computer vision ; image processing
Sažetak
In this paper we have proposed and evaluated a new method for human anthropometric parameters estimation. Method is planed to be simple and fast, thus suited for examiners with no experience in the anthropometric measurements. An anthropometric data obtained by this method, segments masses and lengths, are primarily used for biomechanics applications, but could be adapted to other fields, as well. Estimates of segment inertial properties are frequently based on data and procedures developed for human cadavers in whom inertial properties have been measured directly, using complicated and time consuming procedures. For that reason, we have designed a measurement system that consists of singe digital camera, PC and requires simple experimental set?up with a few considerations. Proposed method comes with some disadvantages, due to which it could be rather used as an estimation tool than as a highly6precise measurement procedure of anthropometric parameters. Measurement using proposed method is completely contactless with the subject, which result in minimizing examiners physical intervention and considerable reduction of time required for measurements. Therefore, measurement procedure is adopted to be executed on a large number of subjects in short time. An algorithm was developed that creates 3D model of the human body using only data obtained from 2D subject?s image, and ellipses as basic building objects. Finally, results of anthropometric body parameters obtained for three subjects were compared with referent anthropometric data and manual measurement.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika
POVEZANOST RADA
Projekti:
MZOS-023-0232006-1655 - Biomehanika ljudskih pokreta, upravljanje i rehabilitacija (Zanchi, Vlasta, MZOS ) ( CroRIS)
Ustanove:
Fakultet elektrotehnike, strojarstva i brodogradnje, Split
Citiraj ovu publikaciju:
Časopis indeksira:
- Scopus
Uključenost u ostale bibliografske baze podataka::
- Compendex (EI Village)
- EMBASE (Excerpta Medica)
- Fluidex (Fluid Engineering Abstracts)
- Geobase
- INSPEC
- MathSciNet
- Zentrallblatt für Mathematik/Mathematical Abstracts