Pregled bibliografske jedinice broj: 404639
Dynamic Behavior for Some Nonlinearity Correcting Methods in Industrial Platinum Resistance Thermometer
Dynamic Behavior for Some Nonlinearity Correcting Methods in Industrial Platinum Resistance Thermometer // SICE Annual Conference 2009, International Conference on Instrumentation, Control and Information Technology / Nakamura, Masatoshi ; Choi, Jin Seog (ur.).
Fukuoka: The Society of Instrument and Control Engineers (SICE), Japan ; The Institute of Control, Robotics and Systems (ICROS), Korea, 2009. str. 3131-3134 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 404639 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Dynamic Behavior for Some Nonlinearity Correcting Methods in Industrial Platinum Resistance Thermometer
Autori
Hocenski, Željko ; Cvitaš, Ljubivoj
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
SICE Annual Conference 2009, International Conference on Instrumentation, Control and Information Technology
/ Nakamura, Masatoshi ; Choi, Jin Seog - Fukuoka : The Society of Instrument and Control Engineers (SICE), Japan ; The Institute of Control, Robotics and Systems (ICROS), Korea, 2009, 3131-3134
Skup
SICE Annual Conference 2009, International Conference on Instrumentation, Control and Information Technology
Mjesto i datum
Fukuoka, Japan, 18.08.2009. - 21.08.2009
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
temperature measurement; correction; method; transmitter
Sažetak
The comparison of dynamic behavior for several methods for nonlinearity correction of Platinum resistance industrial thermometers in production phase is presented in this paper. The measuring temperature transducer is based on microcontroller with an algorithm, so the conversion of resistance to temperature is done. As the measuring sensor has nonlinear transfer function it is necessary to make its correction. There are several methods and several algorithms to do this based on Callender - van Dusen method. This comparison is performed for six versions of microcontroller software used for temperature measuring transducer. The dynamic behavior in this paper includes execution time and step response analysis. Based on this analysis transducer design could result in faster processing and response.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika, Računarstvo
POVEZANOST RADA
Projekti:
165-0361621-2000 - Distribuirano računalno upravljanje u transportu i industrijskim pogonima (Hocenski, Željko, MZO ) ( CroRIS)
165-0362980-2002 - Postupci raspoređivanja u samoodrživim raspodijeljenim računalnim sustavima (Martinović, Goran, MZO ) ( CroRIS)
Ustanove:
Fakultet elektrotehnike, računarstva i informacijskih tehnologija Osijek