Pregled bibliografske jedinice broj: 400886
The human body exposed to a magnetotherapy device magnetic field
The human body exposed to a magnetotherapy device magnetic field // Eighth International Conference on Modelling in Medicine and Biology VIII (BIOMED) : proceedings / Brebbia, Carlos (ur.).
Southampton: Wessex Institute of Technology Press, 2009. str. 203-211 doi:10.2495/BIO090191 (pozvano predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 400886 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
The human body exposed to a magnetotherapy device magnetic field
Autori
Poljak, Dragan ; Šesnić, Silvestar ; Čavka, Damir ; Titlić, Marina ; Mihalj, Mario
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Eighth International Conference on Modelling in Medicine and Biology VIII (BIOMED) : proceedings
/ Brebbia, Carlos - Southampton : Wessex Institute of Technology Press, 2009, 203-211
ISBN
978-1-84564-183-2
Skup
Eighth International Conference on Modelling in Medicine and Biology (8 ; 2009)
Mjesto i datum
Anissaras, Grčka, 26.05.2009. - 28.05.2009
Vrsta sudjelovanja
Pozvano predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
magnetotherapy ; human exposure to magnetic fields ; disk model of the body ; induced current density
Sažetak
This paper deals with human exposure to extremely low frequency (ELF) magnetic fields generated by a magnetotherapy device. The problem is twofold, i.e. it implies the assessment of an external ELF magnetic field and other internal parameters related to the human body response to this field (total current, power density, total power). Of particular importance is the current density induced inside the human body as the basic restriction proposed by relevant international bodies for non-ionizing radiation, such as ICNIRP. ELF magnetic field levels generated from a magnetotherapy device are obtained from measurement. Knowing the external magnetic field generated by a magnet, the circular current density induced in the human body is obtained by the use of the analytical formula arising from the disk model of the human torso. On computing the circular current density, it is possible to assess other parameters of interest related to body response. The obtained values of both the magnetic field and internal current density are compared to exposure limits in terms of reference levels and basic restrictions proposed by ICNIRP.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika, Javno zdravstvo i zdravstvena zaštita
POVEZANOST RADA
Projekti:
023-0231582-1585 - Modeliranje ljudskog tijela i izvora zračenja:okolišni i zdravstveni aspekti
023-0231582-2294 - Modeliranje i okolišni aspekti ENF elektromagnetskih polja
Ustanove:
Fakultet elektrotehnike, strojarstva i brodogradnje, Split,
Medicinski fakultet, Split
Profili:
Silvestar Šesnić
(autor)
Mario Mihalj
(autor)
Marina Titlić
(autor)
Damir Čavka
(autor)
Dragan Poljak
(autor)