Pregled bibliografske jedinice broj: 396404
Accuracy of routine flow-cytometric bitmap selection for three leukocyte populations
Accuracy of routine flow-cytometric bitmap selection for three leukocyte populations // Cytometry, 10 (1989), 4; 442-447 doi:10.1002/cyto.990100412 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 396404 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Accuracy of routine flow-cytometric bitmap selection for three leukocyte populations
Autori
Sučić, Mirna ; Kolevska, Tanja ; Kopjar, Bojan ; Kosanović, Mirjana ; Drobnjak, Marija ; Žalud, Ivica ; Marušić, Matko
Izvornik
Cytometry (0196-4763) 10
(1989), 4;
442-447
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
leukocytes ; flow cytometry ; bitmap selection
(leukociti ; protočna citometrija ; selekcija bitmapa)
Sažetak
A double-blind study was performed with peripheral blood of 41 human subjects to check the accuracy of determination of lymphocyte, monocyte, and granulocyte windows with which every flow cytometric analysis of leukocyte markers starts. White blood cell suspensions were prepared according to the whole blood method and analyzed on an EPICS-C flow cytometer using the two-parameter 90 degrees light scatter vs. forward angle light scatter (granularity vs. cell size) data distribution. Windows (bitmaps) for lymphocytes, monocytes, and granulocytes were drawn and numbers of cells determined in each. The proportions of lymphocytes, monocytes, and granulocytes were calculated in relation to total cell number, counted and in relation to the sum of cells in three bitmaps, and then compared with proportions determined by microscopic whole blood cell (WBC) differential and a WBC differential determined in an automated hematology analyzer. Average proportions of lymphocytes obtained by the flow cytometer were significantly lower than those obtained by either microscopic or automated differential, suggesting that some of the relevant cells were not included in the bitmaps. Granulocyte proportion related to total cell number was lower and that related to bitmap cell number higher than that obtained by microscopic and automatic differentials, suggesting that nongranulocytic cells were included in the granulocyte bitmaps. Proportions of lymphocytes and granulocytes obtained by the flow cytometer correlated well with those obtained by both microscopic and automatic differential. In contrast, the proportions of monocytes showed a poor correlation, which is probably due to their low number and delicate position in the distribution, and which makes them difficult to delineate.
Izvorni jezik
Engleski
Znanstvena područja
Kliničke medicinske znanosti, Farmacija
POVEZANOST RADA
Projekti:
29-0000000-3385
214-0000000-3385 - Citološki pokazatelji proliferacije stanica
Ustanove:
Farmaceutsko-biokemijski fakultet, Zagreb,
Medicinski fakultet, Zagreb,
Klinička bolnica "Sveti Duh",
Klinički bolnički centar Zagreb
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- SCI-EXP, SSCI i/ili A&HCI
Uključenost u ostale bibliografske baze podataka::
- MEDLINE