Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 392913

High Performance Liquid Chromatography for HEMA detection in SE adhesives


Pandurić, Vlatko; Tarle, Zrinka; Hameršak, Zdenko; Stipetić, Irena; Matošević, Danijela; Janković, Bernard; Negovetić Mandić, Višnja
High Performance Liquid Chromatography for HEMA detection in SE adhesives // Journal of Dental Research, Vol. 88, Special Issue A
Miami (FL), Sjedinjene Američke Države, 2009. (poster, međunarodna recenzija, sažetak, znanstveni)


CROSBI ID: 392913 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
High Performance Liquid Chromatography for HEMA detection in SE adhesives

Autori
Pandurić, Vlatko ; Tarle, Zrinka ; Hameršak, Zdenko ; Stipetić, Irena ; Matošević, Danijela ; Janković, Bernard ; Negovetić Mandić, Višnja

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni

Izvornik
Journal of Dental Research, Vol. 88, Special Issue A / - , 2009

Skup
IADR/AADR/CADR 87th General Session and Exibition

Mjesto i datum
Miami (FL), Sjedinjene Američke Države, 01.04.2009. - 04.04.2009

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
High performance liquid chromatography; self-etching adhesives; HEMA

Sažetak
Objective: One of the factors that can decrease hydrolytic stability of self-etching adhesive systems (SEAS) is 2-hydroxyethylmethacrylate (HEMA). Due to hydrolytic instability of acidic methacrylate monomers in SEAS, HEMA can be present even if the manufacturer did not include it in original composition. The aim of the study was to determine the presence of HEMA G-Bond because of decomposition by hydrolysis of methacrylates during storage, resulting with loss of adhesion strength to hard dental tissues of the tooth crown. Method: Two most commonly used SEAS were tested: G-bond and AdheSE ONE under different storage conditions. High performance liquid chromatography (HPLC) analysis was performed on a Nucleosil C18-100 5 &micro ; ; m (250x4.6 mm) column, Knauer K-501 pumps and Wellchrom DAD K-2700 detector at 215 nm. Data were collected and processed by EuroCrom 2000 HPLC software. Samples of adhesives (~70 mg) were dissolved in 2.0 ml of methanol and filtered ; 20 &micro ; ; l were injected and isocraticaly eluted with 20% aqueous methanol for 15 min, followed by gradient to 100% methanol in 5 min. Calibration curves were made relating eluted peak area to known concentrations of HEMA (purchased from Fluka). The elution time for HEMA is 12.25 min at flow rate 1.0 ml/min. Result: Obtained results indicate that no HEMA was present in AdheSE ONE because methacrylates are substituted with methacrylamides that seem to be more stable under acidic aqueous conditions. HEMA was detected in G-Bond. Conclusion: Special concern should be taken on storage period end storage conditions because HEMA can be produced due to decomposition of methacrylates by hydrolysis during storage.

Izvorni jezik
Engleski

Znanstvena područja
Kemija, Dentalna medicina



POVEZANOST RADA


Projekti:
098-0982933-2908 - Kiralni građevni blokovi za biološki aktivne molekule. Sinteza i reaktivnost (Hameršak, Zdenko, MZOS ) ( CroRIS)
065-0352851-0410 - Nanostruktura restaurativnih materijala i interakcije s tvrdim zubnim tkivima (Tarle, Zrinka, MZOS ) ( CroRIS)

Ustanove:
Stomatološki fakultet, Zagreb,
Institut "Ruđer Bošković", Zagreb


Citiraj ovu publikaciju:

Pandurić, Vlatko; Tarle, Zrinka; Hameršak, Zdenko; Stipetić, Irena; Matošević, Danijela; Janković, Bernard; Negovetić Mandić, Višnja
High Performance Liquid Chromatography for HEMA detection in SE adhesives // Journal of Dental Research, Vol. 88, Special Issue A
Miami (FL), Sjedinjene Američke Države, 2009. (poster, međunarodna recenzija, sažetak, znanstveni)
Pandurić, V., Tarle, Z., Hameršak, Z., Stipetić, I., Matošević, D., Janković, B. & Negovetić Mandić, V. (2009) High Performance Liquid Chromatography for HEMA detection in SE adhesives. U: Journal of Dental Research, Vol. 88, Special Issue A.
@article{article, author = {Panduri\'{c}, Vlatko and Tarle, Zrinka and Hamer\v{s}ak, Zdenko and Stipeti\'{c}, Irena and Mato\v{s}evi\'{c}, Danijela and Jankovi\'{c}, Bernard and Negoveti\'{c} Mandi\'{c}, Vi\v{s}nja}, year = {2009}, keywords = {High performance liquid chromatography, self-etching adhesives, HEMA}, title = {High Performance Liquid Chromatography for HEMA detection in SE adhesives}, keyword = {High performance liquid chromatography, self-etching adhesives, HEMA}, publisherplace = {Miami (FL), Sjedinjene Ameri\v{c}ke Dr\v{z}ave} }
@article{article, author = {Panduri\'{c}, Vlatko and Tarle, Zrinka and Hamer\v{s}ak, Zdenko and Stipeti\'{c}, Irena and Mato\v{s}evi\'{c}, Danijela and Jankovi\'{c}, Bernard and Negoveti\'{c} Mandi\'{c}, Vi\v{s}nja}, year = {2009}, keywords = {High performance liquid chromatography, self-etching adhesives, HEMA}, title = {High Performance Liquid Chromatography for HEMA detection in SE adhesives}, keyword = {High performance liquid chromatography, self-etching adhesives, HEMA}, publisherplace = {Miami (FL), Sjedinjene Ameri\v{c}ke Dr\v{z}ave} }




Contrast
Increase Font
Decrease Font
Dyslexic Font