Characterization of LPM diving-bell manometer


Zvizdic, Davor; Grgec Bermanec, Lovorka; Schultz, Wilfried; Veliki, Tomislav
Characterization of LPM diving-bell manometer // Cultivating metrological knowledge / Jorge Torres Guzman (ur.).
Mérida, Meksiko, 2007. (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 387740 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Characterization of LPM diving-bell manometer

Autori
Zvizdic, Davor ; Grgec Bermanec, Lovorka ; Schultz, Wilfried ; Veliki, Tomislav

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Cultivating metrological knowledge / Jorge Torres Guzman - , 2007

Skup
3rd Conference on Pressure Measurement (together with 20th Conference on Measurement of Force, Mass and Torque & 1st Conference on Vibration Measurement),

Mjesto i datum
Mérida, Meksiko, 27.11.2007. - 30.11.2007

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
Diving-bell manometer; effective area; measurement uncertainty

Sažetak
This paper presents characterization of diving-bell manometer in the gauge pressure range from -1.0 up to 3.0 kPa in the Croatian national pressure laboratory - Laboratory for Process measurement (LPM), located at the Faculty of Mechanical Engineering and Naval Architecture (FSB), University of Zagreb. The work points out comparison of two independent methods for diving-bell effective area determination i.e. determination based on dimensional measurements as well as determination of the effective area by a pressure comparison method. The dimensional measurements were performed in the Croatian national length laboratory, also at FSB. Determination of the effective area by the pressure comparison method was performed in LPM using a Physikalisch-Technische Bundesanstalt (PTB) Rosemount pressure transducer previously calibrated in PTB Braunschweig. From the results it can be seen that the difference in the effective areas obtained with the two independent methods is very small compared to the estimated effective area measurement uncertainties.

Izvorni jezik
Engleski

Znanstvena područja
Strojarstvo



POVEZANOST RADA


Projekti:
120-0000000-3322 - Razvoj nacionalnog etalona temperature (Zvizdić, Davor, MZOS ) ( CroRIS)

Ustanove:
Fakultet strojarstva i brodogradnje, Zagreb

Citiraj ovu publikaciju:

Zvizdic, Davor; Grgec Bermanec, Lovorka; Schultz, Wilfried; Veliki, Tomislav
Characterization of LPM diving-bell manometer // Cultivating metrological knowledge / Jorge Torres Guzman (ur.).
Mérida, Meksiko, 2007. (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Zvizdic, D., Grgec Bermanec, L., Schultz, W. & Veliki, T. (2007) Characterization of LPM diving-bell manometer. U: Jorge Torres Guzman (ur.)Cultivating metrological knowledge.
@article{article, author = {Zvizdic, Davor and Grgec Bermanec, Lovorka and Schultz, Wilfried and Veliki, Tomislav}, year = {2007}, keywords = {Diving-bell manometer, effective area, measurement uncertainty}, title = {Characterization of LPM diving-bell manometer}, keyword = {Diving-bell manometer, effective area, measurement uncertainty}, publisherplace = {M\'{e}rida, Meksiko} }
@article{article, author = {Zvizdic, Davor and Grgec Bermanec, Lovorka and Schultz, Wilfried and Veliki, Tomislav}, year = {2007}, keywords = {Diving-bell manometer, effective area, measurement uncertainty}, title = {Characterization of LPM diving-bell manometer}, keyword = {Diving-bell manometer, effective area, measurement uncertainty}, publisherplace = {M\'{e}rida, Meksiko} }




Contrast
Increase Font
Decrease Font
Dyslexic Font