Three-electrode cell set-up electrical equivalent circuit applied to impedance analysis of thin polyaniline film modified electrodes


Horvat-Radošević, Višnja; Kvastek, Krešimir
Three-electrode cell set-up electrical equivalent circuit applied to impedance analysis of thin polyaniline film modified electrodes // Journal of electroanalytical chemistry, 631 (2009), 1-2; 10-21 doi:10.1016/j.jelechem.2009.03.003 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 387146 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Three-electrode cell set-up electrical equivalent circuit applied to impedance analysis of thin polyaniline film modified electrodes

Autori
Horvat-Radošević, Višnja ; Kvastek, Krešimir

Izvornik
Journal of electroanalytical chemistry (1572-6657) 631 (2009), 1-2; 10-21

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
three-electrode cell set-up EEC ; impedance spectroscopy ; parasitic stray impedance ;

Sažetak
The whole three-electrode cell set-up electrical equivalent circuit, EEC, involving parasitic stray impedance is applied in the analysis of impedance spectra of thin polyaniline, PANI, film modified working electrodes in conditions of gradually reduced films and changes of the solution resistance term. It is shown that the frequency region of parasitic stray impedance response is determined by two characteristic time constants of three-electrode cell. The values of time constants are determined by total stray capacity and total stray inductivity of the cell and solution resistance formed between the working and reference electrodes. A type of frequency response of parasitic stray impedance (almost capacitive or almost inductive) is determined by the higher time constant. Extent of influence of parasitic stray impedance on the recorded impedance spectra is determined by impedance of the working electrode and solution resistance. Neglect of contribution of parasitic stray impedance to impedance spectra, particularly of low and moderately high electrode impedance(s) such as PANI film modified electrode in conducting and partially reduced state(s) in electrolyte solutions of high(er) conductivity, will always result in rather uncertain values of the evaluated model parameters.

Izvorni jezik
Engleski

Znanstvena područja
Kemija, Kemijsko inženjerstvo



POVEZANOST RADA


Projekti:
098-0982904-2905 - Elektroaktivni filmovi za ekološki prihvatljivu konverziju i pohranu energije (Horvat-Radošević, Višnja, MZOS ) ( CroRIS)
125-1252973-2576 - Temeljna i primijenjena istraživanja vodljivih polimera (Mandić, Zoran, MZOS ) ( CroRIS)

Ustanove:
Institut "Ruđer Bošković", Zagreb,
Fakultet kemijskog inženjerstva i tehnologije, Zagreb

Poveznice na cjeloviti tekst rada:

doi www.sciencedirect.com doi.org

Citiraj ovu publikaciju:

Horvat-Radošević, Višnja; Kvastek, Krešimir
Three-electrode cell set-up electrical equivalent circuit applied to impedance analysis of thin polyaniline film modified electrodes // Journal of electroanalytical chemistry, 631 (2009), 1-2; 10-21 doi:10.1016/j.jelechem.2009.03.003 (međunarodna recenzija, članak, znanstveni)
Horvat-Radošević, V. & Kvastek, K. (2009) Three-electrode cell set-up electrical equivalent circuit applied to impedance analysis of thin polyaniline film modified electrodes. Journal of electroanalytical chemistry, 631 (1-2), 10-21 doi:10.1016/j.jelechem.2009.03.003.
@article{article, author = {Horvat-Rado\v{s}evi\'{c}, Vi\v{s}nja and Kvastek, Kre\v{s}imir}, year = {2009}, pages = {10-21}, DOI = {10.1016/j.jelechem.2009.03.003}, keywords = {three-electrode cell set-up EEC, impedance spectroscopy, parasitic stray impedance, }, journal = {Journal of electroanalytical chemistry}, doi = {10.1016/j.jelechem.2009.03.003}, volume = {631}, number = {1-2}, issn = {1572-6657}, title = {Three-electrode cell set-up electrical equivalent circuit applied to impedance analysis of thin polyaniline film modified electrodes}, keyword = {three-electrode cell set-up EEC, impedance spectroscopy, parasitic stray impedance, } }
@article{article, author = {Horvat-Rado\v{s}evi\'{c}, Vi\v{s}nja and Kvastek, Kre\v{s}imir}, year = {2009}, pages = {10-21}, DOI = {10.1016/j.jelechem.2009.03.003}, keywords = {three-electrode cell set-up EEC, impedance spectroscopy, parasitic stray impedance, }, journal = {Journal of electroanalytical chemistry}, doi = {10.1016/j.jelechem.2009.03.003}, volume = {631}, number = {1-2}, issn = {1572-6657}, title = {Three-electrode cell set-up electrical equivalent circuit applied to impedance analysis of thin polyaniline film modified electrodes}, keyword = {three-electrode cell set-up EEC, impedance spectroscopy, parasitic stray impedance, } }