Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 386156

Local effects of atomizing analyte droplets on the plasma parameters of the inductively coupled plasma


Groh, Sebastian; Garcia, Carmen C.; Murtazin, Ayrat; Horvatić, Vlasta; Niemax, Kay
Local effects of atomizing analyte droplets on the plasma parameters of the inductively coupled plasma // Spectrochimica Acta Part B, 64 (2009), 3; 247-254 doi:10.1016/j.sab.2009.02.008 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 386156 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Local effects of atomizing analyte droplets on the plasma parameters of the inductively coupled plasma

Autori
Groh, Sebastian ; Garcia, Carmen C. ; Murtazin, Ayrat ; Horvatić, Vlasta ; Niemax, Kay

Izvornik
Spectrochimica Acta Part B (0584-8547) 64 (2009), 3; 247-254

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Inductively coupled plasma; single droplet injection; analyte atomization; plasma parameters; matrix effects

Sažetak
Monodisperse droplets from aqueous analyte solutions with selected diameters in the range 35 – 67 µ ; m are introduced into an inductively coupled plasma with frequencies between 1 to 10 droplets per second. The effect of desolvation and atomization in the ICP is studied end-on by optical emission spectroscopy employing simultaneously up to three calibrated monochromators with fast photomultipliers. The onsets of desolvation and analyte atomization and the extremely fast diffusion of hydrogen in the ICP and its effect on the plasma are studied by simultaneous measurements of hydrogen, analyte and Ar lines. The local cooling by analyte atomization as well as the recovering of the plasma excitation temperature after completed atomization is measured quantitatively in dependence on time applying the Boltzmann plot method to simultaneously recorded line intensities of atomized analyte atoms which act as plasma probes. Furthermore, it is shown that relatively small differences in analyte mass cause significant temperature changes during atomization and, as consequence, strong variations of the emission intensity of analyte lines during atomization if measured by end-on observation.

Izvorni jezik
Engleski

Znanstvena područja
Fizika



POVEZANOST RADA


Projekti:
035-0352851-2853 - Spektroskopija Rydbergovih atoma i molekula (Horvatić, Vlasta, MZOS ) ( CroRIS)

Ustanove:
Institut za fiziku, Zagreb

Profili:

Avatar Url Vlasta Horvatić (autor)

Citiraj ovu publikaciju:

Groh, Sebastian; Garcia, Carmen C.; Murtazin, Ayrat; Horvatić, Vlasta; Niemax, Kay
Local effects of atomizing analyte droplets on the plasma parameters of the inductively coupled plasma // Spectrochimica Acta Part B, 64 (2009), 3; 247-254 doi:10.1016/j.sab.2009.02.008 (međunarodna recenzija, članak, znanstveni)
Groh, S., Garcia, C., Murtazin, A., Horvatić, V. & Niemax, K. (2009) Local effects of atomizing analyte droplets on the plasma parameters of the inductively coupled plasma. Spectrochimica Acta Part B, 64 (3), 247-254 doi:10.1016/j.sab.2009.02.008.
@article{article, author = {Groh, Sebastian and Garcia, Carmen C. and Murtazin, Ayrat and Horvati\'{c}, Vlasta and Niemax, Kay}, year = {2009}, pages = {247-254}, DOI = {10.1016/j.sab.2009.02.008}, keywords = {Inductively coupled plasma, single droplet injection, analyte atomization, plasma parameters, matrix effects}, journal = {Spectrochimica Acta Part B}, doi = {10.1016/j.sab.2009.02.008}, volume = {64}, number = {3}, issn = {0584-8547}, title = {Local effects of atomizing analyte droplets on the plasma parameters of the inductively coupled plasma}, keyword = {Inductively coupled plasma, single droplet injection, analyte atomization, plasma parameters, matrix effects} }
@article{article, author = {Groh, Sebastian and Garcia, Carmen C. and Murtazin, Ayrat and Horvati\'{c}, Vlasta and Niemax, Kay}, year = {2009}, pages = {247-254}, DOI = {10.1016/j.sab.2009.02.008}, keywords = {Inductively coupled plasma, single droplet injection, analyte atomization, plasma parameters, matrix effects}, journal = {Spectrochimica Acta Part B}, doi = {10.1016/j.sab.2009.02.008}, volume = {64}, number = {3}, issn = {0584-8547}, title = {Local effects of atomizing analyte droplets on the plasma parameters of the inductively coupled plasma}, keyword = {Inductively coupled plasma, single droplet injection, analyte atomization, plasma parameters, matrix effects} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font