Pregled bibliografske jedinice broj: 385021
Can ultrasound be useful for predicting the size of a left double-lumen bronchial tube? Tracheal width as measured by ultrasonography versus computed tomography.
Can ultrasound be useful for predicting the size of a left double-lumen bronchial tube? Tracheal width as measured by ultrasonography versus computed tomography. // Journal of Clinical Anesthesia, 20 (2008), 4; 247-252 (recenziran, članak, stručni)
CROSBI ID: 385021 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Can ultrasound be useful for predicting the size of a left double-lumen bronchial tube? Tracheal width as measured by ultrasonography versus computed tomography.
Autori
Šustić, Alan ; Miletić, Damir ; Protić, Alen ; Ivančić, Aldo ; Cicvarić, Tedi
Izvornik
Journal of Clinical Anesthesia (0952-8180) 20
(2008), 4;
247-252
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, stručni
Ključne riječi
Thoracic anesthesia; Double-lumen endobronchial tube; Ultrasonography
Sažetak
Study Objective: To correlate tracheal width as measured by ultrasound with width measured by computed tomography (CT), and to evaluate the possible role of ultrasound in the selection of the proper size of left-sided double-lumen endotracheal tubes (LDLTs). Design: Two independent, prospective, observational clinical studies (Study 1 and Study 2). Setting: University hospital. Patients: Study 1 included 25 patients and Study 2 included 20 adult thoracic surgery patients who required a LDLT during anesthesia. Interventions and Measurements: In Study 1, CT measurements of tracheal width were made at the coronary plane 0.5 cm above the sternoclavicular joint ; CT measurements of the left main bronchus diameter were made 1 cm below the carina. Ultrasound measurement of tracheal width was performed just above the sternoclavicular joint in the transversal section. In Study 2, patients' tracheas were intubated with a LDLT based on ultrasound measurements. The frequencies of incorrect selections of LDLT and unsatisfactory lung collapse were analyzed. Main Results: There was a strong correlation between tracheal width as measured by ultrasound and tracheal width (r=0.882, P<0.001) and left main bronchus width (r=0.832, P<0.001) as measured by CT. In 5 cases (25%), the incorrect LDLT by ultrasound was selected ; and one (5%) was found to have an unsatisfactory lung collapse. Conclusion: Measurement of the outer tracheal width by ultrasound can be a useful method for predicting the diameter of left main bronchus and for selecting a LDLT.
Izvorni jezik
Engleski
Znanstvena područja
Kliničke medicinske znanosti
POVEZANOST RADA
Projekti:
062-0000000-0220 - Perkutana traheostomija u prevenciji pneumonije u strojno ventiliranih bolesnika (Šustić, Alan, MZOS ) ( CroRIS)
Ustanove:
Medicinski fakultet, Rijeka,
Klinički bolnički centar Rijeka
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE