Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 384381

Axial vs. angular dynamization of anterior cervical fusion implants


Stančić, Marin; Margetić, Petra; Elabjer, Esmat; Milošević, Milan
Axial vs. angular dynamization of anterior cervical fusion implants // Collegium Antropologicum, 32 (2008), 1; 221-229 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 384381 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Axial vs. angular dynamization of anterior cervical fusion implants

Autori
Stančić, Marin ; Margetić, Petra ; Elabjer, Esmat ; Milošević, Milan

Izvornik
Collegium Antropologicum (0350-6134) 32 (2008), 1; 221-229

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
surgical procedure; anterior; cervical plate; myelopathy; decompression; cervical fusion

Sažetak
Aim of our study was to compare anterior cervical fusion with fusion augmented with dynamic implants and with the first generation H-plate. Methods. Patients with radiculopathy and/or myelopathy were included in a prospective cohort study. Clinical outcome was assessed according to the Nurick, Odom, and SF 36 scales. Rotation and translation of screws, and quality of fusion (Tribus) were assessed at the 6- week and 4-year follow- up examinations. Neurodecom- pression was performed in 81 patients (one-level N=45, two- level N=26 and multi-level N=10) in the period from Janu- ary 2001 to September 2003. 50 male and 31 female patients were divided into three groups, depending upon type of fu- sion: 1. Augmented with dynamic implants (N=33), 2. Augmented with H-plate (N=33), and 3. Non-augmented (N= 15), one-level. There were no significant differences in clinical outcomes between the groups. Dynamization was detected in both augmented groups: axial in the dynamic implant group (mean translation ± SD = 2.67 ± 0.79 mm), and angular in the H-plate group (angle of rotation 7.2° ± 3.04°). Six-week fusion was significantly better in the dynamic implants and non-augmented groups, as compared with the H-plate group. Two patients in the H-plate group developed pseudo- arthrosis, 7 patients in the dynamic implant group had supradjacent segment heterotopic ossification and two of these additional ankylosis. Three patients in the non- augmented group had dislodgement of the bone graft with transient dysphagia in one of them. Our results suggest that selection of implants is not crucial for clinical outcome. Subsidence is allowed with both fixation systems. Fusion is faster and more effective in the axially dynamized group.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Projekti:
151-2192376-3140 - Biomehanika distrakcije u liječenju nestabilnih prijeloma kralježnice (Stančić, Marin, MZOS ) ( CroRIS)

Ustanove:
Klinički bolnički centar Zagreb

Profili:

Avatar Url Petra Margetić (autor)

Avatar Url Marin Stančić (autor)

Avatar Url Esmat Elabjer (autor)

Poveznice na cjeloviti tekst rada:

Pristup cjelovitom tekstu rada

Citiraj ovu publikaciju:

Stančić, Marin; Margetić, Petra; Elabjer, Esmat; Milošević, Milan
Axial vs. angular dynamization of anterior cervical fusion implants // Collegium Antropologicum, 32 (2008), 1; 221-229 (međunarodna recenzija, članak, znanstveni)
Stančić, M., Margetić, P., Elabjer, E. & Milošević, M. (2008) Axial vs. angular dynamization of anterior cervical fusion implants. Collegium Antropologicum, 32 (1), 221-229.
@article{article, author = {Stan\v{c}i\'{c}, Marin and Margeti\'{c}, Petra and Elabjer, Esmat and Milo\v{s}evi\'{c}, Milan}, year = {2008}, pages = {221-229}, keywords = {surgical procedure, anterior, cervical plate, myelopathy, decompression, cervical fusion}, journal = {Collegium Antropologicum}, volume = {32}, number = {1}, issn = {0350-6134}, title = {Axial vs. angular dynamization of anterior cervical fusion implants}, keyword = {surgical procedure, anterior, cervical plate, myelopathy, decompression, cervical fusion} }
@article{article, author = {Stan\v{c}i\'{c}, Marin and Margeti\'{c}, Petra and Elabjer, Esmat and Milo\v{s}evi\'{c}, Milan}, year = {2008}, pages = {221-229}, keywords = {surgical procedure, anterior, cervical plate, myelopathy, decompression, cervical fusion}, journal = {Collegium Antropologicum}, volume = {32}, number = {1}, issn = {0350-6134}, title = {Axial vs. angular dynamization of anterior cervical fusion implants}, keyword = {surgical procedure, anterior, cervical plate, myelopathy, decompression, cervical fusion} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Social Science Citation Index (SSCI)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE





Contrast
Increase Font
Decrease Font
Dyslexic Font