Pregled bibliografske jedinice broj: 375700
Application of Meteosat SEVIRI channel difference 0.6 μ m - 1.6 μ m in convective cells detection
Application of Meteosat SEVIRI channel difference 0.6 μ m - 1.6 μ m in convective cells detection // Atmospheric research, 93 (2009), 1-3 (Special Issue); 270-276 doi:10.1016/j.atmosres.2008.10.023 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 375700 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Application of Meteosat SEVIRI channel difference 0.6 μ m - 1.6 μ m in convective cells detection
Autori
Strelec Mahović, Nataša ; Zeiner, Barbara
Izvornik
Atmospheric research (0169-8095) 93
(2009), 1-3 (Special Issue);
270-276
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
convective clouds detection; 0.6 μ m - 1.6 μ m channel difference; operational application
Sažetak
Convective cells detecting algorithms, used in operational weather services, are frequently based on single infra-red channel data. Due to many disadvantages of these methods, an attempt is made to introduce the difference of Meteosat SEVIRI channels 0.6 μ m and 1.6 μ m as a tool for automatic recognition of convective clouds. The differences of reflectance values of the two channels were calculated for numerous cases and the results were visually compared to radar reflectivity data. The comparison shows that all potentially dangerous cells are detected which means promising and operationally applicable result. Due to the fact that satellite radiometer sees particles of a much smaller size than the radar does, the difference method suggested here enables the recognition of small developing cells several time-steps (up to one hour) before they are seen in the radar imagery, provided that a proper threshold is set for the difference values. This enables the detection of convective cells in the areas not covered by radar measurements. It is also shown that the detection provided by the channel difference method is much more precise and detailed than the detection based on the IR channel data. The main disadvantage of the method is the fact that it can be used only during daytime, so the night-time convection needs to be treated separately.
Izvorni jezik
Engleski
Znanstvena područja
Geologija
POVEZANOST RADA
Projekti:
004-1193086-3036 - Oluje i prirodne katastrofe u Hrvatskoj (Ivančan-Picek, Branka, MZOS ) ( CroRIS)
Ustanove:
Državni hidrometeorološki zavod
Profili:
Nataša Strelec-Mahović
(autor)
Poveznice na cjeloviti tekst rada:
Pristup cjelovitom tekstu rada doi dx.doi.org www.sciencedirect.comCitiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus