Pregled bibliografske jedinice broj: 367333
Resolution and peak asymmetry modelling in gradient elution ion chromatography
Resolution and peak asymmetry modelling in gradient elution ion chromatography // 14th International Symposium on Separation Science, New Achievements in Chromatography, Book of Abstracts / Šegudović, Nikola (ur.).
Zagreb: Hrvatsko društvo kemijskih inženjera i tehnologa (HDKI), 2008. str. 168-168 (poster, međunarodna recenzija, sažetak, znanstveni)
CROSBI ID: 367333 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Resolution and peak asymmetry modelling in gradient elution ion chromatography
Autori
Cerjan Stefanović, Štefica ; Bolanča, Tomislav ; Ukić, Šime ; Rogošić, Marko ; Rupić, Danijela
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
14th International Symposium on Separation Science, New Achievements in Chromatography, Book of Abstracts
/ Šegudović, Nikola - Zagreb : Hrvatsko društvo kemijskih inženjera i tehnologa (HDKI), 2008, 168-168
ISBN
978-953-6894-36-9
Skup
14th International Symposium on Separation Science, New Achievements in Chromatography
Mjesto i datum
Primošten, Hrvatska, 30.09.2008. - 03.10.2008
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
ion chromatography; resolution; modelling; gradient elution
Sažetak
The separation is usually, globally optimized by taking into account exclusively the retention times of solutes which enables a fast and simple calculation. However, this is suitable for modeling chromatograms that include symmetrical peaks and show similar plate count. Inclusion of the peak size and shape in the optimization process might be of interest when asymmetric or low-efficiency peaks are involved, or when poorly separated symmetrical peaks are observed. There is no universal theoretical model for the exact description of the shape of chromatographic peaks. The aim of this work is development of gradient elution retention model that can be applied for modelling of resolution and peak asymmetry in ion chromatography. Developed gradient elution retention model is based on isocratic experimental data enabling fast and simple modelling of various gradient profiles. This study shows extensive error analysis of developed gradient elution model in order to verify its performance characteristics.
Izvorni jezik
Engleski
Znanstvena područja
Kemija, Kemijsko inženjerstvo
POVEZANOST RADA
Projekti:
125-1253092-3004 - Procesi ionske izmjene u sustavu kvalitete industrijskih voda (Bolanča, Tomislav, MZOS ) ( CroRIS)
Ustanove:
Fakultet kemijskog inženjerstva i tehnologije, Zagreb
Profili:
Tomislav Bolanča
(autor)
Marko Rogošić
(autor)
Štefica Cerjan-Stefanović
(autor)
Šime Ukić
(autor)