Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 364303

Determination of High-Resolution Digital Voltmeter Input Parameters


Leniček, Ivan; Ilić, Damir; Malarić, Roman
Determination of High-Resolution Digital Voltmeter Input Parameters // IEEE Transactions on Instrumentation and Measurement, 57 (2008), 8; 1685-1688 doi:10.1109/TIM.2008.928556 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 364303 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Determination of High-Resolution Digital Voltmeter Input Parameters

Autori
Leniček, Ivan ; Ilić, Damir ; Malarić, Roman

Izvornik
IEEE Transactions on Instrumentation and Measurement (0018-9456) 57 (2008), 8; 1685-1688

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Digital voltmeter (DVM); input capacitance; input offset current; input resistance

Sažetak
High resolution digital voltmeter can be widely used when precise measurements are needed, but input circuitry can contribute to the results of measurement. Therefore, to make uncertainty of measurement as small as possible for a particular measurement, it is necessary to characterize its input parameters. In this paper the methods for the determination of input resistance, capacitance and input offset current of the precise digital voltmeters HP 3458A with 8½ ; digits resolution are presented. The method with voltage source and high-ohmic divider resistor has been developed for the determination both the input offset current IS, as well as the input resistance RV. The second method with source of linear voltage ramp and picoampermeter is primary used for the determination of input capacitance CV. It was shown that: input offset current of voltmeters is in the range of picoamperes, with relative instability of approximately +/-0.1 ; input resistance is in the range of teraohm with the same relative instability of +/-0.1 ; and the input capacitance was measured to be in the range of few hundred picofarads with an uncertainty of a few picofarads.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Projekti:
036-0363081-1648 - Umjeravanje i mjerenje podržano Internetom (Malarić, Roman, MZO ) ( CroRIS)
036-0363081-1650 - Mjerenje elektromagnetskih veličina na etalonskoj razini (Ilić, Damir, MZO ) ( CroRIS)

Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb

Profili:

Avatar Url Ivan Leniček (autor)

Avatar Url Roman Malarić (autor)

Avatar Url Damir Ilić (autor)

Poveznice na cjeloviti tekst rada:

doi

Citiraj ovu publikaciju:

Leniček, Ivan; Ilić, Damir; Malarić, Roman
Determination of High-Resolution Digital Voltmeter Input Parameters // IEEE Transactions on Instrumentation and Measurement, 57 (2008), 8; 1685-1688 doi:10.1109/TIM.2008.928556 (međunarodna recenzija, članak, znanstveni)
Leniček, I., Ilić, D. & Malarić, R. (2008) Determination of High-Resolution Digital Voltmeter Input Parameters. IEEE Transactions on Instrumentation and Measurement, 57 (8), 1685-1688 doi:10.1109/TIM.2008.928556.
@article{article, author = {Leni\v{c}ek, Ivan and Ili\'{c}, Damir and Malari\'{c}, Roman}, year = {2008}, pages = {1685-1688}, DOI = {10.1109/TIM.2008.928556}, keywords = {Digital voltmeter (DVM), input capacitance, input offset current, input resistance}, journal = {IEEE Transactions on Instrumentation and Measurement}, doi = {10.1109/TIM.2008.928556}, volume = {57}, number = {8}, issn = {0018-9456}, title = {Determination of High-Resolution Digital Voltmeter Input Parameters}, keyword = {Digital voltmeter (DVM), input capacitance, input offset current, input resistance} }
@article{article, author = {Leni\v{c}ek, Ivan and Ili\'{c}, Damir and Malari\'{c}, Roman}, year = {2008}, pages = {1685-1688}, DOI = {10.1109/TIM.2008.928556}, keywords = {Digital voltmeter (DVM), input capacitance, input offset current, input resistance}, journal = {IEEE Transactions on Instrumentation and Measurement}, doi = {10.1109/TIM.2008.928556}, volume = {57}, number = {8}, issn = {0018-9456}, title = {Determination of High-Resolution Digital Voltmeter Input Parameters}, keyword = {Digital voltmeter (DVM), input capacitance, input offset current, input resistance} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Uključenost u ostale bibliografske baze podataka::


  • INSPEC


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font