Pregled bibliografske jedinice broj: 361196
Resolution and peak asymmetry modelling in gradient elution ion chromatography
Resolution and peak asymmetry modelling in gradient elution ion chromatography // 10th International School of Ion Chromatography, Book of Abstracts / Bolanča, Tomislav ; Ukić, Šime ; Margeta, Karmen (ur.).
Zagreb: Fakultet kemijskog inženjerstva i tehnologije Sveučilišta u Zagrebu, 2008. str. 40-40 (poster, međunarodna recenzija, sažetak, znanstveni)
CROSBI ID: 361196 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Resolution and peak asymmetry modelling in gradient elution ion chromatography
Autori
Cerjan Stefanović, Štefica ; Bolanča, Tomislav ; Ukić, Šime ; Rogošić, Marko ; Rupić, Danijela
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
10th International School of Ion Chromatography, Book of Abstracts
/ Bolanča, Tomislav ; Ukić, Šime ; Margeta, Karmen - Zagreb : Fakultet kemijskog inženjerstva i tehnologije Sveučilišta u Zagrebu, 2008, 40-40
ISBN
978-953-6470-40-2
Skup
10th International School of Ion Chromatography
Mjesto i datum
Brijuni, Hrvatska, 03.06.2008. - 06.06.2008
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
resolution; peak asymmetry; modelling; gradient elution; ion chromatography
Sažetak
A major challenge in the development of ion chromatographic separation methods is the rational selection of optimal experimental conditions that can provide an adequate separation and a reasonable run time. The reliability of an optimization procedure depends on quality of the retention behaviour description for all compounds present in the mixture followed by sufficiently informative criterion function used to measure the separation between each pair chromatographic peaks. When using retention models for global optimization of separation very often, only the retention times of solutes are taken into account enabling fast and simple procedure. This is suitable for comparing chromatograms if all peaks are symmetrical and show similar plate count. Inclusion of resolution and the peak asymmetry in the optimisation process is not only essential when asymmetrical or low-efficiency peaks are involved, but also in situations where symmetrical peaks are very close to each other. The aim of this work is development of gradient elution retention model that can be applied for modelling of resolution and peak asymmetry in ion chromatography. Developed gradient elution retention model is based on isocratic experimental data enabling fast and simple modelling of various gradient profiles. This study shows extensive error analysis of developed gradient elution model in order to verify its performance characteristics.
Izvorni jezik
Engleski
Znanstvena područja
Kemijsko inženjerstvo
POVEZANOST RADA
Projekti:
125-1253092-3004 - Procesi ionske izmjene u sustavu kvalitete industrijskih voda (Bolanča, Tomislav, MZOS ) ( CroRIS)
Ustanove:
Fakultet kemijskog inženjerstva i tehnologije, Zagreb
Profili:
Tomislav Bolanča
(autor)
Marko Rogošić
(autor)
Štefica Cerjan-Stefanović
(autor)
Šime Ukić
(autor)