Pregled bibliografske jedinice broj: 359126
Pseudoexfoliation syndrome and asymptomatic myocardial dysfunction
Pseudoexfoliation syndrome and asymptomatic myocardial dysfunction // Graefes Archive for Clinical and Experimental Ophthalmology, 243 (2005), 5; 446-449 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 359126 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Pseudoexfoliation syndrome and asymptomatic myocardial dysfunction
Autori
Bojić, Lovro ; Ermacora, Ratko ; Polić, Stojan ; Ivanisević, Milan ; Mandić, Zlatko, Rogosić, Velimir ; Lesin, Milan
Izvornik
Graefes Archive for Clinical and Experimental Ophthalmology (0721-832X) 243
(2005), 5;
446-449
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
pseudoexfoliation syndrome; myocardial diastolic dysfunction
Sažetak
BACKGROUND: The purpose of this study was to investigate the frequency of asymptomatic left ventricular dysfunction in patients with pseudoexfoliation syndrome. METHODS: Two-dimensional and pulsed Doppler echocardiography of transmitral flow was performed on 27 patients with pseudoexfoliation syndrome, aged 66.9+/-5.6 years, and 24 healthy volunteers aged 63.9+/-6.5 years. Left ventricular (LV) systolic contraction and ejection were assessed by LV ejection fraction (EF) and fractional shortening (FS). LV diastolic filling parameters tested were: early fast diastolic filling (E wave), late diastolic filling (A wave), ratio E/A, velocity time integral E wave (VTIE) and A wave (VTIA), their ratio (VTIE/VTIA), pressure at the end of filling (LVEDP) and a pulmonary capillary wedge pressure (PCWP). RESULTS: Systolic parameters EF and FS, diastolic filling parameters such as A, LVEDP and PCWP were not significantly different between patients with pseudoexfoliation syndrome and controls (P>0.05). A significant difference (P<0.05) was found with regard to the diastolic filling parameters: E (61.6+/-15.1 vs 83.7+/-21.4), ratio E/A (0.8+/-0.1 vs 1.1+/-0.2), VTIE (8.6+/-1.8 vs 9.8+/-1.9), VTIA (10.3+/-2.4 vs 7.8+/-1.6) and ratio VTIA/VTIE (1.2+/-0.2 vs 0.8+/-0.2). CONCLUSION: Our study suggests the possibility of an association between patients with pseudoexfoliation syndrome and a discrete asymptomatic myocardial diastolic dysfunction.
Izvorni jezik
Engleski
Znanstvena područja
Kliničke medicinske znanosti
POVEZANOST RADA
Ustanove:
KBC Split,
Medicinski fakultet, Split
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE
Uključenost u ostale bibliografske baze podataka::
- MEDLINE