Beam tests of lead tungstate crystal matrices and a silicon strip preshower detector for the CMS electromagnetic calorimeter
Beam tests of lead tungstate crystal matrices and a silicon strip preshower detector for the CMS electromagnetic calorimeter // Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 412 (1998), 2/3; 223-227 doi:10.1016/S0168-9002(98)00464-1 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 35473 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Beam tests of lead tungstate crystal matrices and a silicon strip preshower detector for the CMS electromagnetic calorimeter
Autori
Auffray, E. ; Baillon, P. ; Barney, D. ; Bassompierre, G. ; Benhammou, Y. ; Blick, A. ; Bloch, P. ; Bonamy, P. ; Bourotte, J. ; Buiron, L. ; Cavallari, F. ; Chipaux, R. ; Cockerill, D. ; Dafinei, I. ; Davies, G. ; Depasse, P. ; Deiters, K. ; Diemoz, M. ; Dobrzynski, L. ; Donskov, S. ; El Mamouni, H. ; Ercoli, C. ; Faure, J.L. ; Felcini, M. ; Gautheron, F. ; Geleoc, M ; Givernaud, A. ; Gninenko, S. ; Godinović, Nikola ; Graham, D.J. ; Guillaud, J.P. ; Guschin, E. ; Hagenauer, M. ; Hillemanns, H. ; Hofer, H. ; Ille, B. ; Inyakin, A. ; Jaaskelainen, S. ; Katchanov, V. ; Kirn, T. ; Kloukinas, K. ; Korzhik, M. ; Lassila-Perini, K. ; Lebrun, P. ; Locoq, P. ; Lecoeur, G. ; Lecompte, P. ; Leonardi, E. ; Locci, E. ; Loos, R. ; Longo, E. ; Mackay, C. ; Martin, E. ; Martin, F. ; Mendiburu, J.P. ; Musienko, Y. ; Nedelec, P. ; Nessi-Tedaldi, F. ; Organtini, G. ; Paoletti, S. ; Pansart, J.P. ; Peigneux, J.P. ; Puljak, Ivica ; Qian, S. ; Reid, E. ; Renker, D. ; Rosowsky, A. ; Rosso, E. ; Rusack, R. ; Rykaczewski, H. ; Schneegans, M. ; Seez, C. ; Semeniouk, I. ; Shagin, P. ; Sillou, D. ; Singovsky, A. ; Sougonyaev, V. ; Sorić, Ivica ; Verrecchia, P. ; Vialle, J.P. ; Virdee, T.S. ; Zhu, R.Y.
Izvornik
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (0168-9002) 412
(1998), 2/3;
223-227
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
lead tungstate; preshower; CMS; APD; energy resolution; irradiation; monitoring
Sažetak
Test of lead tungstate crystal matrices carried out in high-energy electron beams in 1996, using new crystals, new APDs and an improved test set-up, confirm that an energy resolution of better than 0.6% at 100 GeV can be obtained when the longitudinal uniformity of the struck crystal is adequate. Light loss measurements under low dose irradiation are reported. It is shown that there is no loss of energy resolution after irradiation and that the calibration change due to light loss can be tracked with a precision monitoring system. Finally, successful test with a preshower device, equipped with silicon strip detector readout are described.
Izvorni jezik
Engleski
Znanstvena područja
Fizika
POVEZANOST RADA
Projekti:
023052
Ustanove:
Fakultet elektrotehnike, strojarstva i brodogradnje, Split,
Sveučilište u Splitu
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus