Pregled bibliografske jedinice broj: 352910
The Analysis of The Unstable Tibia Fracture Treatment Applying Internal Stabilization Method
The Analysis of The Unstable Tibia Fracture Treatment Applying Internal Stabilization Method // Collegium antropologicum, 31 (2007), 4; 1015-1018 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 352910 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
The Analysis of The Unstable Tibia Fracture Treatment Applying Internal Stabilization Method
Autori
Lovrić, Ivan ; Has, Borislav ; Jovanović, Savo ; Lekšan, Igor ; Radić, Radivoje ; Rapan, Saša ; Rukavina, Milan
Izvornik
Collegium antropologicum (0350-6134) 31
(2007), 4;
1015-1018
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
unstable tibia fracture; fractures tibiae; tibial nail; plate; osteitis
Sažetak
The study included 51 patients with tibia fractures, who underwent percutaneous bone reposition and stabilization with unrimed tibial locking nail. The results obtained using this method were compared with those obtained by standard fracture treatment where flat and anatomic plates were applied (n=64). In patients who had osteosynthetic material implanted percutaneously (using unrimed tibial locking nail) there was no incidence of post surgical osteitis or any pseudarthrosis. The healing callus of the fracture was of lesser quality and spindle shaped, suggesting that fracture stabilization using this method was less efficient. Inpatients with fractures stabilized by the open method using flat and anatomic plates (n=64), we noticed 3.1% (n=2) cases of osteitis and 4.7% (n=3) cases of pseudarthrosis. Due to lesser incidence of postoperative osteitis, our method of choice in tibia fractures would be percutaneous stabilization with unrimed tibial locking nail. However, this treatment method has its disadvantages, too. Fracture callus is of lesser quality and it is spindle shaped. Furthermore, there are problems with adequate percutaneous reposition in some cases ; as well as necessity for radiological checking.
Izvorni jezik
Engleski
Znanstvena područja
Temeljne medicinske znanosti, Kliničke medicinske znanosti
POVEZANOST RADA
Projekti:
219-2192376-2092 - Biomehanika čvrstih organskih tkiva (Nikolić, Vasilije, MZOS ) ( CroRIS)
219-2192376-2379 - Biomehanička optimalizacija nekih postupaka u ortopediji (Jovanović, Savo, MZOS ) ( CroRIS)
Ustanove:
Medicinski fakultet, Osijek
Profili:
Ivan Lovrić
(autor)
Savo Jovanović
(autor)
Saša Rapan
(autor)
Radivoje Radić
(autor)
Borislav Has
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Social Science Citation Index (SSCI)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE