Pregled bibliografske jedinice broj: 349702
Image intensity standardization in 3D rotational angiography and its application to vascular segmentation
Image intensity standardization in 3D rotational angiography and its application to vascular segmentation // Proceedings of SPIE -- Volume 6914, Medical Imaging 2008: Image Processing / Reinnhardt, Joseph ; Pluim, Josien (ur.).
San Diego (CA), Sjedinjene Američke Države: SPIE, 2008. (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 349702 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Image intensity standardization in 3D rotational angiography and its application to vascular segmentation
Autori
Bogunović, Hrvoje ; Radaelli, Alessandro ; De Craene, Mathieu ; Delgado, David ; Frangi, Alejandro
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of SPIE -- Volume 6914, Medical Imaging 2008: Image Processing
/ Reinnhardt, Joseph ; Pluim, Josien - : SPIE, 2008
Skup
SPIE Medical Imaging
Mjesto i datum
San Diego (CA), Sjedinjene Američke Države, 16.02.2008. - 21.02.2008
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
vascular segmentation
Sažetak
Knowledge-based vascular segmentation methods typically rely on a pre-built training set of segmented images, which is used to estimate the probability of each voxel to belong to a particular tissue. In 3D Rotational Angiography (3DRA) the same tissue can correspond to different intensity ranges depending on the imaging device, settings and contrast injection protocol. As a result, pre-built training sets do not apply to all images and the best segmentation results are often obtained when the training set is built specifically for each individual image. We present an Image Intensity Standardization (IIS) method designed to ensure a correspondence between specific tissues and intensity ranges common to every image that undergoes the standardization process. The method applies a piecewise linear transformation to the image that aligns the intensity histogram to the histogram taken as reference. The reference histogram has been selected from a high quality image not containing artificial objects such as coils or stents. This is a pre-processing step that allows employing a training set built on a limited number of standardized images for the segmentation of standardized images which were not part of the training set. The effectiveness of the presented IIS technique in combination with a well-validated knowledge-based vasculature segmentation method is quantified on a variety of 3DRA images depicting cerebral arteries and intracranial aneurysms. The proposed IIS method offers a solution to the standardization of tissue classes in routine medical images and effectively improves automation and usability of knowledge-based vascular segmentation algorithms.
Izvorni jezik
Engleski
Znanstvena područja
Računarstvo
POVEZANOST RADA
Projekti:
036-0362214-1989 - Inteligentne metode obrade i analize slika (Lončarić, Sven, MZO ) ( CroRIS)
Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb
Profili:
Hrvoje Bogunović
(autor)