Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 348014

A new highly sensitive potentiometric sensor for low levels of anionic surfactants in effluents


Sak-Bosnar, Milan; Madunić-Čačić, Dubravka; Kovačević, Mirela; Grabarić, Božidar S.
A new highly sensitive potentiometric sensor for low levels of anionic surfactants in effluents // 1st Regional Symposium on Electrochemistry of South-East Europe : Book of abstracts / Gojo, Miroslav ; Horvat-Radošević, Višnja ; Mandić, Zoran (ur.).
Zagreb: Hrvatsko društvo kemijskih inženjera i tehnologa (HDKI), 2008. str. 342-343 (poster, domaća recenzija, sažetak, znanstveni)


CROSBI ID: 348014 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
A new highly sensitive potentiometric sensor for low levels of anionic surfactants in effluents

Autori
Sak-Bosnar, Milan ; Madunić-Čačić, Dubravka ; Kovačević, Mirela ; Grabarić, Božidar S.

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni

Izvornik
1st Regional Symposium on Electrochemistry of South-East Europe : Book of abstracts / Gojo, Miroslav ; Horvat-Radošević, Višnja ; Mandić, Zoran - Zagreb : Hrvatsko društvo kemijskih inženjera i tehnologa (HDKI), 2008, 342-343

ISBN
978-953-6894-33-8

Skup
Regional Symposium on Electrochemisty of South-East Europe (1 ; 2008)

Mjesto i datum
Rovinj, Hrvatska, 04.05.2008. - 08.05.2008

Vrsta sudjelovanja
Poster

Vrsta recenzije
Domaća recenzija

Ključne riječi
potentiometric sensor; anionic surfactants; effluents

Sažetak
A new highly sensitive surfactant-selective liquid membrane electrode based on 1, 3-didecyl-2-methyl-imidazolium-tetraphenylborate (DMI-TPB) ion-exchange complex as a sensing material has been prepared [4]. In the investigations described DMI-TPB sensor was tested for determination of anionic surfactants in effluents. The sensor responded fast and exhibited a Nernstian response. Its main application was indication of the end-point in ion-pair surfactant potentiometric titrations. DMI-TPB sensor exhibits excellent selectivity performances for DS over almost all organic and inorganic anions investigated. The organic and inorganic anions commonly used in surfactant based industrial and household formulations, do not interfere in anionic surfactant potentiometric determination. The mixed solution method  5 has been used for measurement of selectivity coefficients. The sensor is used for titration of diluted industrial detergent products without pretreatment, except for those containing complexed surfactant mixture, where pH adjustment was needed. It was used for the monitoring of anionic surfactants in industrial wastewaters too, without pretreatment, except filtration when necessary. The equivalence points of slightly distorted titration curves or those with poorer and noisy inflexions can be calculated using multiple point parabola fit. The results obtained agree satisfactory with standard extraction-spectrophotometric MBAS (Methylene Blue Active Substance) method [6] for low concentration of anionic surfactants in effluents and surface waters. The average lifetime of the membrane was at least six months, depending on the nature of the analytes.

Izvorni jezik
Engleski

Znanstvena područja
Kemija



POVEZANOST RADA


Projekti:
058-0580000-3071 - Razvoj kemometričkih i senzorskih metoda određivanja različitih analita (Ninčević Grassino, Antonela, MZOS ) ( CroRIS)
291-0580000-0169 - Kemijski senzori za primjenu u biomedicini, hrani i zaštiti okoliša (Sak-Bosnar, Milan, MZOS ) ( CroRIS)

Ustanove:
Prehrambeno-biotehnološki fakultet, Zagreb


Citiraj ovu publikaciju:

Sak-Bosnar, Milan; Madunić-Čačić, Dubravka; Kovačević, Mirela; Grabarić, Božidar S.
A new highly sensitive potentiometric sensor for low levels of anionic surfactants in effluents // 1st Regional Symposium on Electrochemistry of South-East Europe : Book of abstracts / Gojo, Miroslav ; Horvat-Radošević, Višnja ; Mandić, Zoran (ur.).
Zagreb: Hrvatsko društvo kemijskih inženjera i tehnologa (HDKI), 2008. str. 342-343 (poster, domaća recenzija, sažetak, znanstveni)
Sak-Bosnar, M., Madunić-Čačić, D., Kovačević, M. & Grabarić, B. (2008) A new highly sensitive potentiometric sensor for low levels of anionic surfactants in effluents. U: Gojo, M., Horvat-Radošević, V. & Mandić, Z. (ur.)1st Regional Symposium on Electrochemistry of South-East Europe : Book of abstracts.
@article{article, author = {Sak-Bosnar, Milan and Maduni\'{c}-\v{C}a\v{c}i\'{c}, Dubravka and Kova\v{c}evi\'{c}, Mirela and Grabari\'{c}, Bo\v{z}idar S.}, year = {2008}, pages = {342-343}, keywords = {potentiometric sensor, anionic surfactants, effluents}, isbn = {978-953-6894-33-8}, title = {A new highly sensitive potentiometric sensor for low levels of anionic surfactants in effluents}, keyword = {potentiometric sensor, anionic surfactants, effluents}, publisher = {Hrvatsko dru\v{s}tvo kemijskih in\v{z}enjera i tehnologa (HDKI)}, publisherplace = {Rovinj, Hrvatska} }
@article{article, author = {Sak-Bosnar, Milan and Maduni\'{c}-\v{C}a\v{c}i\'{c}, Dubravka and Kova\v{c}evi\'{c}, Mirela and Grabari\'{c}, Bo\v{z}idar S.}, year = {2008}, pages = {342-343}, keywords = {potentiometric sensor, anionic surfactants, effluents}, isbn = {978-953-6894-33-8}, title = {A new highly sensitive potentiometric sensor for low levels of anionic surfactants in effluents}, keyword = {potentiometric sensor, anionic surfactants, effluents}, publisher = {Hrvatsko dru\v{s}tvo kemijskih in\v{z}enjera i tehnologa (HDKI)}, publisherplace = {Rovinj, Hrvatska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font