Effects of background substraction on differential kidney function measured by static scintigraphy with DMSA and dynamic scintigraphy with MAG 3


Girotto, Neva; Smokvina, Aleksandar; Ivanković Grbac, Svjetlana; Licul, Vanja
Effects of background substraction on differential kidney function measured by static scintigraphy with DMSA and dynamic scintigraphy with MAG 3 // Nuklearmedizin, 47 (2008), 1; 43-47 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 342068 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Effects of background substraction on differential kidney function measured by static scintigraphy with DMSA and dynamic scintigraphy with MAG 3

Autori
Girotto, Neva ; Smokvina, Aleksandar ; Ivanković Grbac, Svjetlana ; Licul, Vanja

Izvornik
Nuklearmedizin (0029-5566) 47 (2008), 1; 43-47

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
kidney; Tc-99m-DMSA; Tc-99m-MAG3; scintigraphy; differential function; background subtraction

Sažetak
The aim of this study was to assess the influence of background subtraction (BS) on estimation of differential kidney function (DF) on the static scintigraphy with Tc-99m dimercaptosuccinic acid (DMSA) and dynamic scintigraphy with Tc-99m mercaptoacetyltriglicine (MAG3) and to establish possible differences between DF values estimated with these methods. Patients, methods: Patients (n = 106) were selected among those scheduled to static and dynamic scintigraphies within 3 months, with no interim clinical and laboratory changes, regardless the kidney pathology. DF was estimated according to the uptake ratio method. Four background regions of interest (ROls) were applied, identical for both studies, and DF values were recalculated after BS. The corrected values were compared to the values before correction, separately for DMSA and MAG3, and between the studies. The results showed that ROls used introduce variable results for the some patients, predominantly when noncorrected DF values were < 45%. There were no significant differences between DF values (corrected and noncorrected) obtained from static and dynamic scintigraphy in all groups of patients. Since numerous reasons can bring to the errors in DF estimation when BS is used, the conclusions ore that it would probably be more accurate to avoid BS, particularly when DF values are compared in a patient follow-up, and when kidney function is normal. BS should he used, but always in the same way, only when there is a significant difference in kidney size, or when DF is < 25%, since background activity is then considerable. MAG3 and DMSA can be equally used for DF estimation and their results compared in patient follow-up.

Izvorni jezik
Engleski

Znanstvena područja
Temeljne medicinske znanosti



POVEZANOST RADA


Ustanove:
Klinički bolnički centar Rijeka


Citiraj ovu publikaciju:

Girotto, Neva; Smokvina, Aleksandar; Ivanković Grbac, Svjetlana; Licul, Vanja
Effects of background substraction on differential kidney function measured by static scintigraphy with DMSA and dynamic scintigraphy with MAG 3 // Nuklearmedizin, 47 (2008), 1; 43-47 (međunarodna recenzija, članak, znanstveni)
Girotto, N., Smokvina, A., Ivanković Grbac, S. & Licul, V. (2008) Effects of background substraction on differential kidney function measured by static scintigraphy with DMSA and dynamic scintigraphy with MAG 3. Nuklearmedizin, 47 (1), 43-47.
@article{article, author = {Girotto, Neva and Smokvina, Aleksandar and Ivankovi\'{c} Grbac, Svjetlana and Licul, Vanja}, year = {2008}, pages = {43-47}, keywords = {kidney, Tc-99m-DMSA, Tc-99m-MAG3, scintigraphy, differential function, background subtraction}, journal = {Nuklearmedizin}, volume = {47}, number = {1}, issn = {0029-5566}, title = {Effects of background substraction on differential kidney function measured by static scintigraphy with DMSA and dynamic scintigraphy with MAG 3}, keyword = {kidney, Tc-99m-DMSA, Tc-99m-MAG3, scintigraphy, differential function, background subtraction} }
@article{article, author = {Girotto, Neva and Smokvina, Aleksandar and Ivankovi\'{c} Grbac, Svjetlana and Licul, Vanja}, year = {2008}, pages = {43-47}, keywords = {kidney, Tc-99m-DMSA, Tc-99m-MAG3, scintigraphy, differential function, background subtraction}, journal = {Nuklearmedizin}, volume = {47}, number = {1}, issn = {0029-5566}, title = {Effects of background substraction on differential kidney function measured by static scintigraphy with DMSA and dynamic scintigraphy with MAG 3}, keyword = {kidney, Tc-99m-DMSA, Tc-99m-MAG3, scintigraphy, differential function, background subtraction} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE





Contrast
Increase Font
Decrease Font
Dyslexic Font