Pregled bibliografske jedinice broj: 329366
Determination of cationic surfactants in pharmaceutical disinfectants using a new sensitive potentiometric sensor
Determination of cationic surfactants in pharmaceutical disinfectants using a new sensitive potentiometric sensor // Talanta, 76 (2008), 2; 259-264 doi:10.1016/j.talanta.2008.02.023 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 329366 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Determination of cationic surfactants in pharmaceutical disinfectants using a new sensitive potentiometric sensor
Autori
Madunić-Čačić, Dubravka ; Sak-Bosnar, Milan ; Galović, Olivera ; Sakač, Nikola ; Matešić-Puač, Ružica
Izvornik
Talanta (0039-9140) 76
(2008), 2;
259-264
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
surfactant sensor; PVC membrane; cationic surfactant; potentiometric titration; pharmaceuticals
Sažetak
A new sensitive potentiometric surfactant sensor was prepared based on a highly lipophilic 1, 3-didecyl-2-methyl-imidazolium cation and a tetraphenylborate antagonist ion. This sensor was used as a sensing material and incorporated into the plasticized PVC-membrane. The sensor responded fast and showed a Nernstian response for investigated surfactant cations: cetylpyridinium chloride (CPC), hexadecyltrimethylammonium bromide (CTAB) and Hyamine with slope 59.8, 58.6 and 56.8 mV/decade, respectively. The sensor served as an end-point detector in ion-pair surfactant potentiometric titrations using sodium tetraphenylborate as titrant. Several technical grade cationic surfactants and a few commercial disinfectant products were also titrated, and the results were compared with those obtained from a two-phase standard titration method. The sensor showed satisfactory analytical performances within a pH range of 2– 11, and exhibited excellent selectivity performance for CPC compared to all of the organic and inorganic cations investigated. The influence of the nonionic surfactants on the shape of titration curves was negligible if the mass ratio of ethoxylated nonionic surfactants and cationic surfactants (EONS:CS) was not greater than 5.
Izvorni jezik
Engleski
Znanstvena područja
Kemija
POVEZANOST RADA
Projekti:
291-0580000-0169 - Kemijski senzori za primjenu u biomedicini, hrani i zaštiti okoliša (Sak-Bosnar, Milan, MZOS ) ( CroRIS)
Ustanove:
Sveučilište u Osijeku - Odjel za kemiju
Profili:
Nikola Sakač
(autor)
Olivera Galović
(autor)
Milan Sak-Bosnar
(autor)
Dubravka Madunić-Čačić
(autor)
Ružica Matešić-Puač
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE