Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 329366

Determination of cationic surfactants in pharmaceutical disinfectants using a new sensitive potentiometric sensor


Madunić-Čačić, Dubravka; Sak-Bosnar, Milan; Galović, Olivera; Sakač, Nikola; Matešić-Puač, Ružica
Determination of cationic surfactants in pharmaceutical disinfectants using a new sensitive potentiometric sensor // Talanta, 76 (2008), 2; 259-264 doi:10.1016/j.talanta.2008.02.023 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 329366 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Determination of cationic surfactants in pharmaceutical disinfectants using a new sensitive potentiometric sensor

Autori
Madunić-Čačić, Dubravka ; Sak-Bosnar, Milan ; Galović, Olivera ; Sakač, Nikola ; Matešić-Puač, Ružica

Izvornik
Talanta (0039-9140) 76 (2008), 2; 259-264

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
surfactant sensor; PVC membrane; cationic surfactant; potentiometric titration; pharmaceuticals

Sažetak
A new sensitive potentiometric surfactant sensor was prepared based on a highly lipophilic 1, 3-didecyl-2-methyl-imidazolium cation and a tetraphenylborate antagonist ion. This sensor was used as a sensing material and incorporated into the plasticized PVC-membrane. The sensor responded fast and showed a Nernstian response for investigated surfactant cations: cetylpyridinium chloride (CPC), hexadecyltrimethylammonium bromide (CTAB) and Hyamine with slope 59.8, 58.6 and 56.8 mV/decade, respectively. The sensor served as an end-point detector in ion-pair surfactant potentiometric titrations using sodium tetraphenylborate as titrant. Several technical grade cationic surfactants and a few commercial disinfectant products were also titrated, and the results were compared with those obtained from a two-phase standard titration method. The sensor showed satisfactory analytical performances within a pH range of 2– 11, and exhibited excellent selectivity performance for CPC compared to all of the organic and inorganic cations investigated. The influence of the nonionic surfactants on the shape of titration curves was negligible if the mass ratio of ethoxylated nonionic surfactants and cationic surfactants (EONS:CS) was not greater than 5.

Izvorni jezik
Engleski

Znanstvena područja
Kemija



POVEZANOST RADA


Projekti:
291-0580000-0169 - Kemijski senzori za primjenu u biomedicini, hrani i zaštiti okoliša (Sak-Bosnar, Milan, MZOS ) ( CroRIS)

Ustanove:
Sveučilište u Osijeku - Odjel za kemiju

Poveznice na cjeloviti tekst rada:

doi

Citiraj ovu publikaciju:

Madunić-Čačić, Dubravka; Sak-Bosnar, Milan; Galović, Olivera; Sakač, Nikola; Matešić-Puač, Ružica
Determination of cationic surfactants in pharmaceutical disinfectants using a new sensitive potentiometric sensor // Talanta, 76 (2008), 2; 259-264 doi:10.1016/j.talanta.2008.02.023 (međunarodna recenzija, članak, znanstveni)
Madunić-Čačić, D., Sak-Bosnar, M., Galović, O., Sakač, N. & Matešić-Puač, R. (2008) Determination of cationic surfactants in pharmaceutical disinfectants using a new sensitive potentiometric sensor. Talanta, 76 (2), 259-264 doi:10.1016/j.talanta.2008.02.023.
@article{article, author = {Maduni\'{c}-\v{C}a\v{c}i\'{c}, Dubravka and Sak-Bosnar, Milan and Galovi\'{c}, Olivera and Saka\v{c}, Nikola and Mate\v{s}i\'{c}-Pua\v{c}, Ru\v{z}ica}, year = {2008}, pages = {259-264}, DOI = {10.1016/j.talanta.2008.02.023}, keywords = {surfactant sensor, PVC membrane, cationic surfactant, potentiometric titration, pharmaceuticals}, journal = {Talanta}, doi = {10.1016/j.talanta.2008.02.023}, volume = {76}, number = {2}, issn = {0039-9140}, title = {Determination of cationic surfactants in pharmaceutical disinfectants using a new sensitive potentiometric sensor}, keyword = {surfactant sensor, PVC membrane, cationic surfactant, potentiometric titration, pharmaceuticals} }
@article{article, author = {Maduni\'{c}-\v{C}a\v{c}i\'{c}, Dubravka and Sak-Bosnar, Milan and Galovi\'{c}, Olivera and Saka\v{c}, Nikola and Mate\v{s}i\'{c}-Pua\v{c}, Ru\v{z}ica}, year = {2008}, pages = {259-264}, DOI = {10.1016/j.talanta.2008.02.023}, keywords = {surfactant sensor, PVC membrane, cationic surfactant, potentiometric titration, pharmaceuticals}, journal = {Talanta}, doi = {10.1016/j.talanta.2008.02.023}, volume = {76}, number = {2}, issn = {0039-9140}, title = {Determination of cationic surfactants in pharmaceutical disinfectants using a new sensitive potentiometric sensor}, keyword = {surfactant sensor, PVC membrane, cationic surfactant, potentiometric titration, pharmaceuticals} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font