Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 328181

Air washer as a means of air conditioning


Halasz, Boris
Air washer as a means of air conditioning // Proceedings of the 22nd International Congress of Refrigeration
Peking, 2007. (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 328181 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Air washer as a means of air conditioning

Autori
Halasz, Boris

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Proceedings of the 22nd International Congress of Refrigeration / - Peking, 2007

Skup
The 22nd International Congress of Refrigeration

Mjesto i datum
Peking, Kina, 21.08.2007. - 26.08.2007

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
air washer; evaporation; heat transfer; mass transfer; air humidification; air conditioning;

Sažetak
Air washer is mostly used for the purpose of humidifying the air or just washing it (as a wet filter). In both these cases, water temperature is not controlled and is usually near to the inlet air wet bulb temperature. Air condition has the tendency to approach the saturation state at the inlet air wet bulb temperature. By controlling the water temperature and its flow rate, a limited control of air outlet condition can be achieved. Using the hot or cold inlet water can cause air to approach the saturation state at some other temperature, higher or lower than the inlet air wet bulb temperature. With sufficiently low water temperature air can even be dehumidified (as in dehumidifying coils)! The heat and mass transfer process in an air washer can be described using the general nondimensional mathematical model of evaporative cooling devices (published earlier). It correlates the air condition change to the area of the water air interface, the flow direction of water relative to air, and their respective flow rates. The finally obtained overall rating procedure is an algebraic routine which can be used either to calculate air outlet condition (if the water air interface area is known), or the required area for the desired air outlet condition. The only data that cannot be resolved within this (or any other) model is the water air interface area – it should be measured on the device for few water and air flow rates. The procedure is reasonably simple and its results can be estimated as accurate enough for the purpose.

Izvorni jezik
Engleski

Znanstvena područja
Strojarstvo



POVEZANOST RADA


Projekti:
120-1201760-1757 - Izmjena topline i mase u fluidiziranom sloju

Ustanove:
Fakultet strojarstva i brodogradnje, Zagreb

Profili:

Avatar Url Boris Halasz (autor)


Citiraj ovu publikaciju:

Halasz, Boris
Air washer as a means of air conditioning // Proceedings of the 22nd International Congress of Refrigeration
Peking, 2007. (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Halasz, B. (2007) Air washer as a means of air conditioning. U: Proceedings of the 22nd International Congress of Refrigeration.
@article{article, author = {Halasz, Boris}, year = {2007}, keywords = {air washer, evaporation, heat transfer, mass transfer, air humidification, air conditioning, }, title = {Air washer as a means of air conditioning}, keyword = {air washer, evaporation, heat transfer, mass transfer, air humidification, air conditioning, }, publisherplace = {Peking, Kina} }
@article{article, author = {Halasz, Boris}, year = {2007}, keywords = {air washer, evaporation, heat transfer, mass transfer, air humidification, air conditioning, }, title = {Air washer as a means of air conditioning}, keyword = {air washer, evaporation, heat transfer, mass transfer, air humidification, air conditioning, }, publisherplace = {Peking, Kina} }




Contrast
Increase Font
Decrease Font
Dyslexic Font