Two-phase heat transfer during refrigerant evaporation in a solar collector tube


Soldo, Vladimir; Grozdek, Marino; Ćurko, Tonko
Two-phase heat transfer during refrigerant evaporation in a solar collector tube // Conference Proceedings / Asdrubali, Francesco (ur.).
Perugia: Morlakija, 2006. str. 207-212 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 327975 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Two-phase heat transfer during refrigerant evaporation in a solar collector tube

Autori
Soldo, Vladimir ; Grozdek, Marino ; Ćurko, Tonko

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Conference Proceedings / Asdrubali, Francesco - Perugia : Morlakija, 2006, 207-212

ISBN
88-6074-050-9

Skup
International Session: "Solar Heating and Cooling"

Mjesto i datum
Perugia, Italija, 14.09.2006

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
Heat transfer; evaporation; solar collector

Sažetak
The paper presents the calculation of heat transfer in a tube of the solar collector (evaporator) where the refrigerant R134a evaporates. The test system used consists of a compressor, a freon-water compact plate condenser, an electronic expansion valve and two parallel unglazed solar collectors. The solar-assisted heat pump with direct expansion of the refrigerant in the solar collector uses the solar irradiation and the ambient temperature as a heat source on the evaporator. The heat transfer in the two-phase flow of the refrigerant in a horizontal tube is expressed by the expressions taken over from the VDI Wärmeatlas. The effect of the mass velocity G (kg/(m2 s)), the heat flux based on the inner surface of the tube q (W/m2) and the vapour quality x on the heat transfer coefficient in the heat pump solar collector is recorded. Results of calculation have shown that the nucleate boiling is dominant in the first part of the evaporator-collector, while in the second part of the evaporator, with the increase in vapour quality, the convective evaporation prevails.

Izvorni jezik
Engleski



POVEZANOST RADA


Profili:

Avatar Url Vladimir Soldo (autor)

Avatar Url Tonko Ćurko (autor)

Avatar Url Marino Grozdek (autor)


Citiraj ovu publikaciju:

Soldo, Vladimir; Grozdek, Marino; Ćurko, Tonko
Two-phase heat transfer during refrigerant evaporation in a solar collector tube // Conference Proceedings / Asdrubali, Francesco (ur.).
Perugia: Morlakija, 2006. str. 207-212 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Soldo, V., Grozdek, M. & Ćurko, T. (2006) Two-phase heat transfer during refrigerant evaporation in a solar collector tube. U: Asdrubali, F. (ur.)Conference Proceedings.
@article{article, author = {Soldo, Vladimir and Grozdek, Marino and \'{C}urko, Tonko}, editor = {Asdrubali, F.}, year = {2006}, pages = {207-212}, keywords = {Heat transfer, evaporation, solar collector}, isbn = {88-6074-050-9}, title = {Two-phase heat transfer during refrigerant evaporation in a solar collector tube}, keyword = {Heat transfer, evaporation, solar collector}, publisher = {Morlakija}, publisherplace = {Perugia, Italija} }
@article{article, author = {Soldo, Vladimir and Grozdek, Marino and \'{C}urko, Tonko}, editor = {Asdrubali, F.}, year = {2006}, pages = {207-212}, keywords = {Heat transfer, evaporation, solar collector}, isbn = {88-6074-050-9}, title = {Two-phase heat transfer during refrigerant evaporation in a solar collector tube}, keyword = {Heat transfer, evaporation, solar collector}, publisher = {Morlakija}, publisherplace = {Perugia, Italija} }




Contrast
Increase Font
Decrease Font
Dyslexic Font