Pregled bibliografske jedinice broj: 326471
Real-Time Power Angle Determination of Salient-Pole Synchronous Machine Based on Air Gap Measurements
Real-Time Power Angle Determination of Salient-Pole Synchronous Machine Based on Air Gap Measurements // Electric power systems research, 78 (2008), 11; 1873-1880 doi:10.1016/j.epsr.2008.03.013 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 326471 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Real-Time Power Angle Determination of Salient-Pole Synchronous Machine Based on Air Gap Measurements
Autori
Despalatović, Marin ; Jadrić, Martin ; Terzić, Božo
Izvornik
Electric power systems research (0378-7796) 78
(2008), 11;
1873-1880
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
synchronous machines; hydroturbine generator; air gap measurement; power angle
Sažetak
This paper presents a new method for the real-time power angle determination of the salient-pole synchronous machines. This method is based on the terminal voltage and air gap measurements, which are the common features of the hydroturbine generator monitoring system. The raw signal of the air gap sensor is used to detect the rotor displacement with reference to the fundamental component of the terminal voltage. First, the algorithm developed for the real-time power angle determination is tested using the synthetic data obtained by the standard machine model simulation. Thereafter, the experimental investigation is carried out on the 26 MVA utility generator. The validity of the method is verified by comparing with another method, which is based on a tooth gear mounted on the rotor shaft. The proposed real-time algorithm has an adequate accuracy and needs a very short processing time. For applications that do not require real-time processing, such as the estimation of the synchronous machine parameters, the accuracy is additionally increased by applying an off-line data-processing algorithm.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika
POVEZANOST RADA
Projekti:
023-0361621-1611 - Identifikacija parametara sinkronog generatora u pogonu (Terzić, Božo, MZOS ) ( CroRIS)
Ustanove:
Fakultet elektrotehnike, strojarstva i brodogradnje, Split
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus