Potentiometric determination of low levels of anionic and nonionic surfactants in effluents
Potentiometric determination of low levels of anionic and nonionic surfactants in effluents // SARIB Meeting, Sarajevo, 2006
Sarajevo, Bosna i Hercegovina, 2006. (predavanje, međunarodna recenzija, pp prezentacija, znanstveni)
CROSBI ID: 324363 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Potentiometric determination of low levels of anionic and nonionic surfactants in effluents
Autori
Matešić-Puač, Ružica ; Madunić-Čačić, Dubravka ; Sak-Bosnar, Milan ; Grabarić, Zorana ; Grabarić, Božidar S.
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, pp prezentacija, znanstveni
Izvornik
SARIB Meeting, Sarajevo, 2006
/ - , 2006
Skup
SARIB meeting
Mjesto i datum
Sarajevo, Bosna i Hercegovina, 06.04.2006. - 07.04.2006
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
potentiometric sensors; anionic and nonionic surfactants; potentiometric titration; surface waters
Sažetak
The use of potentiometric sensors, commercial and new ones, for determination of anionic and nonionic surfactants in industrial effluents has been presented. The determination was carried out on the modelled effluents formulations as well as on the real industrial effluents. The sensors mentioned served as end-point detector by potentiometric titration of low surfactant concentration levels (down to 10-5 mol dm-3 for anionic surfactants and 10-6 mol dm-3 for nonionic surfactants). No special sample pretreatment was needed, except filtration when necessary. Equivalence point by noisy and flat titration curves was determined using extended least-squares regression formalism of the Savitzky-Golay method. The results for anionic surfactants agree satisfactory with standard extraction-spectrophotometric MBAS method and are comparable with the results obtained using a commercially available surfactant electrode. The accuracy and precision of the nonionic surfactants determination has been evaluated by using standard addition method. Further investigation activities are directed toward increasing of the sensor sensitivity, extending of its linear response range, development of methods for surfactant preconcentration in surface waters.
Izvorni jezik
Engleski
Znanstvena područja
Kemija
POVEZANOST RADA
Projekti:
291-0580000-0169 - Kemijski senzori za primjenu u biomedicini, hrani i zaštiti okoliša (Sak-Bosnar, Milan, MZOS ) ( CroRIS)
Profili:
Božidar Grabarić
(autor)
Milan Sak-Bosnar
(autor)
Ružica Matešić-Puač
(autor)
Dubravka Madunić-Čačić
(autor)
Zorana Grabarić
(autor)