Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 322897

Three-pole metal-enclosed SF6-insulated switchgear, type K8D.6, for voltages from 123 kV to 145 kV


Meštrović, Krešimir
Three-pole metal-enclosed SF6-insulated switchgear, type K8D.6, for voltages from 123 kV to 145 kV // Končar journal, 2 (1989), 2; 24-30 (podatak o recenziji nije dostupan, članak, stručni)


CROSBI ID: 322897 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Three-pole metal-enclosed SF6-insulated switchgear, type K8D.6, for voltages from 123 kV to 145 kV

Autori
Meštrović, Krešimir

Izvornik
Končar journal (0350-5537) 2 (1989), 2; 24-30

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, stručni

Ključne riječi
SF6 gas; metal-enclosed switchgear; circuit breaker; isolator; earthing switch; instrument transformer; busbar; cable connection; calculations; tests; temperature rise

Sažetak
The three-pole metal-enclosed SF6-switchgear type K8D.6, manufactured by Rade Končar, is briefly described, and the problems encountered in designing the elements of this switchgear are indicated. The conductor heating in the isolator-busbar compartment by currents of 1250 A, 1600 A and 2500 A is first computed, and the computation results are compared with the results of the temperature rise test conducted on the same type of switchgear.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Ustanove:
KONČAR - Institut za elektrotehniku d.d.

Profili:

Avatar Url Krešimir Meštrović (autor)


Citiraj ovu publikaciju:

Meštrović, Krešimir
Three-pole metal-enclosed SF6-insulated switchgear, type K8D.6, for voltages from 123 kV to 145 kV // Končar journal, 2 (1989), 2; 24-30 (podatak o recenziji nije dostupan, članak, stručni)
Meštrović, K. (1989) Three-pole metal-enclosed SF6-insulated switchgear, type K8D.6, for voltages from 123 kV to 145 kV. Končar journal, 2 (2), 24-30.
@article{article, author = {Me\v{s}trovi\'{c}, Kre\v{s}imir}, year = {1989}, pages = {24-30}, keywords = {SF6 gas, metal-enclosed switchgear, circuit breaker, isolator, earthing switch, instrument transformer, busbar, cable connection, calculations, tests, temperature rise}, journal = {Kon\v{c}ar journal}, volume = {2}, number = {2}, issn = {0350-5537}, title = {Three-pole metal-enclosed SF6-insulated switchgear, type K8D.6, for voltages from 123 kV to 145 kV}, keyword = {SF6 gas, metal-enclosed switchgear, circuit breaker, isolator, earthing switch, instrument transformer, busbar, cable connection, calculations, tests, temperature rise} }
@article{article, author = {Me\v{s}trovi\'{c}, Kre\v{s}imir}, year = {1989}, pages = {24-30}, keywords = {SF6 gas, metal-enclosed switchgear, circuit breaker, isolator, earthing switch, instrument transformer, busbar, cable connection, calculations, tests, temperature rise}, journal = {Kon\v{c}ar journal}, volume = {2}, number = {2}, issn = {0350-5537}, title = {Three-pole metal-enclosed SF6-insulated switchgear, type K8D.6, for voltages from 123 kV to 145 kV}, keyword = {SF6 gas, metal-enclosed switchgear, circuit breaker, isolator, earthing switch, instrument transformer, busbar, cable connection, calculations, tests, temperature rise} }




Contrast
Increase Font
Decrease Font
Dyslexic Font