Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 322107

Comparison of the responses of several TLDs to various radionuclides


Vekić, Branko; Ranogajec-Komor, Maria; Čukman, Mirela
Comparison of the responses of several TLDs to various radionuclides // Radiation protection dosimetry, 33 (1990), 1-4; 335-338 doi:10.1093/oxfordjournals.rpd.a080824 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 322107 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Comparison of the responses of several TLDs to various radionuclides

Autori
Vekić, Branko ; Ranogajec-Komor, Maria ; Čukman, Mirela

Izvornik
Radiation protection dosimetry (0144-8420) 33 (1990), 1-4; 335-338

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Dosemeters ; radionuclides ; energy dependence

Sažetak
The TL responses of TLD-700, LiF:Mg, Ti, MgB4=7:Dy, CaF2:Mn and Al2O3:Mg, Z dosemeters were calibrated against the radiation of 99-Tc-M (140 keV) and 131-I (80-723 keV) in addition to calibration with 226-Ra (0.093-2.45 MeV) and 137-Cs (0.66 MeV) sources. 99-Tc-m and 131-I are the most commonly used radionuclides in nuclear medicine. According to our previous energy response studies involving X ray irradiations, the TL response of TLD-700, LiF:Mg, Ti and MgB4O7:Dy exhibit low energy dependence. The agreement between the calculated dose and the dose measured by these TLDs is satisfactory, especially in the case of the 131-I source. CaF2:Mn and Al2O3:Mg, Y detectors require special encapsulation for use in the dosimetry of photons in the low energy region.

Izvorni jezik
Engleski

Znanstvena područja
Kemija



POVEZANOST RADA


Ustanove:
Institut "Ruđer Bošković", Zagreb

Profili:

Avatar Url Branko Vekić (autor)

Avatar Url Ferencne Ranogajec (autor)

Poveznice na cjeloviti tekst rada:

doi academic.oup.com

Citiraj ovu publikaciju:

Vekić, Branko; Ranogajec-Komor, Maria; Čukman, Mirela
Comparison of the responses of several TLDs to various radionuclides // Radiation protection dosimetry, 33 (1990), 1-4; 335-338 doi:10.1093/oxfordjournals.rpd.a080824 (međunarodna recenzija, članak, znanstveni)
Vekić, B., Ranogajec-Komor, M. & Čukman, M. (1990) Comparison of the responses of several TLDs to various radionuclides. Radiation protection dosimetry, 33 (1-4), 335-338 doi:10.1093/oxfordjournals.rpd.a080824.
@article{article, author = {Veki\'{c}, Branko and Ranogajec-Komor, Maria and \v{C}ukman, Mirela}, year = {1990}, pages = {335-338}, DOI = {10.1093/oxfordjournals.rpd.a080824}, keywords = {Dosemeters, radionuclides, energy dependence}, journal = {Radiation protection dosimetry}, doi = {10.1093/oxfordjournals.rpd.a080824}, volume = {33}, number = {1-4}, issn = {0144-8420}, title = {Comparison of the responses of several TLDs to various radionuclides}, keyword = {Dosemeters, radionuclides, energy dependence} }
@article{article, author = {Veki\'{c}, Branko and Ranogajec-Komor, Maria and \v{C}ukman, Mirela}, year = {1990}, pages = {335-338}, DOI = {10.1093/oxfordjournals.rpd.a080824}, keywords = {Dosemeters, radionuclides, energy dependence}, journal = {Radiation protection dosimetry}, doi = {10.1093/oxfordjournals.rpd.a080824}, volume = {33}, number = {1-4}, issn = {0144-8420}, title = {Comparison of the responses of several TLDs to various radionuclides}, keyword = {Dosemeters, radionuclides, energy dependence} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font