Thermoluminescence characteristics of various detectors for x ray diagnostic measurements


Ranogajec-Komor, Maria; Muhiy-Ed-Din, Fadwa; Milković, Đurđica; Vekić, Branko
Thermoluminescence characteristics of various detectors for x ray diagnostic measurements // Radiation protection dosimetry, 47 (1993), 1-4; 529-534 doi:10.1093/oxfordjournals.rpd.a081801 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 322088 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Thermoluminescence characteristics of various detectors for x ray diagnostic measurements
(Thermoluminescence characteristics of various detectors for X-ray diagnostic measurements)

Autori
Ranogajec-Komor, Maria ; Muhiy-Ed-Din, Fadwa ; Milković, Đurđica ; Vekić, Branko

Izvornik
Radiation protection dosimetry (0144-8420) 47 (1993), 1-4; 529-534

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Dosimetry ; X-ray diagnostic ; TLD system

Sažetak
The photon energy dependence of LiF:Mg, Cu, P (produced in Poland) as compared to LiF:Mg, Ti, TLD-700 and CaF2:Mn was measured using X rays and 60-Co and 137-Cs gamma ray radiation in two Secondary Standard Dosimetric Laboratories. The reproducibility of the response of all dosimetric systems was also studied at the primary beam of a diagnostic X ray unit. LiF:Mg, Ti and TLD-700 have been used to measure patient doses during chest organ examinations in diagnostic radiology of children to analyse the dose estimations in radiation fields that were not well defined.

Izvorni jezik
Engleski

Znanstvena područja
Kemija



POVEZANOST RADA


Ustanove:
Institut "Ruđer Bošković", Zagreb

Poveznice na cjeloviti tekst rada:

doi academic.oup.com

Citiraj ovu publikaciju:

Ranogajec-Komor, Maria; Muhiy-Ed-Din, Fadwa; Milković, Đurđica; Vekić, Branko
Thermoluminescence characteristics of various detectors for x ray diagnostic measurements // Radiation protection dosimetry, 47 (1993), 1-4; 529-534 doi:10.1093/oxfordjournals.rpd.a081801 (međunarodna recenzija, članak, znanstveni)
Ranogajec-Komor, M., Muhiy-Ed-Din, F., Milković, Đ. & Vekić, B. (1993) Thermoluminescence characteristics of various detectors for x ray diagnostic measurements. Radiation protection dosimetry, 47 (1-4), 529-534 doi:10.1093/oxfordjournals.rpd.a081801.
@article{article, author = {Ranogajec-Komor, Maria and Muhiy-Ed-Din, Fadwa and Milkovi\'{c}, \DJur\djica and Veki\'{c}, Branko}, year = {1993}, pages = {529-534}, DOI = {10.1093/oxfordjournals.rpd.a081801}, keywords = {Dosimetry, X-ray diagnostic, TLD system}, journal = {Radiation protection dosimetry}, doi = {10.1093/oxfordjournals.rpd.a081801}, volume = {47}, number = {1-4}, issn = {0144-8420}, title = {Thermoluminescence characteristics of various detectors for x ray diagnostic measurements}, keyword = {Dosimetry, X-ray diagnostic, TLD system} }
@article{article, author = {Ranogajec-Komor, Maria and Muhiy-Ed-Din, Fadwa and Milkovi\'{c}, \DJur\djica and Veki\'{c}, Branko}, year = {1993}, pages = {529-534}, DOI = {10.1093/oxfordjournals.rpd.a081801}, keywords = {Dosimetry, X-ray diagnostic, TLD system}, journal = {Radiation protection dosimetry}, doi = {10.1093/oxfordjournals.rpd.a081801}, volume = {47}, number = {1-4}, issn = {0144-8420}, title = {Thermoluminescence characteristics of various detectors for X-ray diagnostic measurements}, keyword = {Dosimetry, X-ray diagnostic, TLD system} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font