Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 32201

Flow in collapsible tubes


Mijović, Budimir
Flow in collapsible tubes // Proceedings of the 2nd congress of Croatian Society of Mechanics / Pavao, Marović ; Jurica, Sorić ; Nikola, Vranković (ur.).
Supetar: Hrvatsko društvo za mehaniku (HDM), 1997. str. 615 - 622 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 32201 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Flow in collapsible tubes

Autori
Mijović, Budimir

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Proceedings of the 2nd congress of Croatian Society of Mechanics / Pavao, Marović ; Jurica, Sorić ; Nikola, Vranković - Supetar : Hrvatsko društvo za mehaniku (HDM), 1997, 615 - 622

Skup
Proceedings of the 2nd congress of Croatian Society of Mechanics

Mjesto i datum
Supetar, Hrvatska, 18.09.1997. - 20.09.1997

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
Collapsible; tube; doppler anemometer; vaseular stenoses; differential pressure; bllood vessels of human body

Sažetak
This study used elastic models of thick walled physiological flow conditions. The mode exhibited flow choking when stenoses were greater than 80 % by diameter. The choked flow rates were less than the normal peak systolic flow in human carotid arteries inducating the physiologic range for this phenomenon. Maximum velocities at the throat of the phantoms were approximately 6 m/s, consistent with those measured by Duplex scanning in human carotids. The dynamic pressure conditions contributed to increasing the severity of the elastic stenosis at high velocities. Hemodynamic compression of rupture of carotid plaques.

Izvorni jezik
Engleski

Znanstvena područja
Tekstilna tehnologija



POVEZANOST RADA


Projekti:
117004

Ustanove:
Tekstilno-tehnološki fakultet, Zagreb

Profili:

Avatar Url Budimir Mijović (autor)


Citiraj ovu publikaciju:

Mijović, Budimir
Flow in collapsible tubes // Proceedings of the 2nd congress of Croatian Society of Mechanics / Pavao, Marović ; Jurica, Sorić ; Nikola, Vranković (ur.).
Supetar: Hrvatsko društvo za mehaniku (HDM), 1997. str. 615 - 622 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Mijović, B. (1997) Flow in collapsible tubes. U: Pavao, M., Jurica, S. & Nikola, V. (ur.)Proceedings of the 2nd congress of Croatian Society of Mechanics.
@article{article, author = {Mijovi\'{c}, Budimir}, year = {1997}, pages = {615 - 622}, keywords = {Collapsible, tube, doppler anemometer, vaseular stenoses, differential pressure, bllood vessels of human body}, title = {Flow in collapsible tubes}, keyword = {Collapsible, tube, doppler anemometer, vaseular stenoses, differential pressure, bllood vessels of human body}, publisher = {Hrvatsko dru\v{s}tvo za mehaniku (HDM)}, publisherplace = {Supetar, Hrvatska} }
@article{article, author = {Mijovi\'{c}, Budimir}, year = {1997}, pages = {615 - 622}, keywords = {Collapsible, tube, doppler anemometer, vaseular stenoses, differential pressure, bllood vessels of human body}, title = {Flow in collapsible tubes}, keyword = {Collapsible, tube, doppler anemometer, vaseular stenoses, differential pressure, bllood vessels of human body}, publisher = {Hrvatsko dru\v{s}tvo za mehaniku (HDM)}, publisherplace = {Supetar, Hrvatska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font