Parameter Optimization in Voltage Pulse Plethysmography


Melinščak, Martina
Parameter Optimization in Voltage Pulse Plethysmography // IFMBE Proceedings
Ljubljana, Slovenija, 2007. str. 198-201. (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 308746 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Parameter Optimization in Voltage Pulse Plethysmography

Autori
Melinščak, Martina

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
IFMBE Proceedings / - , 2007, 198-201.

Skup
Medicon 2007 (11th Mediterranean Conference in Medical and Biological Engineering and Computing)

Mjesto i datum
Ljubljana, Slovenija, 26.06.2007. - 30.06.2007

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
voltage pulse plethysmography; electrode tissue interface; tissue resistance variation

Sažetak
Measurement optimization is being studied when short voltage pulses are stimulating bio-tissue and the transient process is sampled in order to measure the tissue volume changes. The measurement sensitivity depends on the ratio of the sampling instant to the time constant of the transient process, (T/t) and on the ratio of the current sensing resistance to the resistance of the electrode-skin interface (R0/RSX). With variations of R0/RSX and T/t the sensitivity changes from negative to positive values, while it equals zero for certain R0/RSX and T/t ratios. The sensitivity is greater when positive while than negative but it depends on T/t and R0/RSX. For negative sensitivity, T and R0 can be chosen to maximize the sensitivity and minimize its variations.Measurement optimization is being studied when short voltage pulses are stimulating bio-tissue and the transient process is sampled in order to measure the tissue volume changes. The measurement sensitivity depends on the ratio of the sampling instant to the time constant of the transient process, (T/t) and on the ratio of the current sensing resistance to the resistance of the electrode-skin interface (R0/RSX). With variations of R0/RSX and T/t the sensitivity changes from negative to positive values, while it equals zero for certain R0/RSX and T/t ratios. The sensitivity is greater when positive while than negative but it depends on T/t and R0/RSX. For negative sensitivity, T and R0 can be chosen to maximize the sensitivity and minimize its variations.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Ustanove:
Veleučilište u Karlovcu

Profili:

Avatar Url Martina Melinščak (autor)

Poveznice na cjeloviti tekst rada:

Pristup cjelovitom tekstu rada

Citiraj ovu publikaciju:

Melinščak, Martina
Parameter Optimization in Voltage Pulse Plethysmography // IFMBE Proceedings
Ljubljana, Slovenija, 2007. str. 198-201. (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Melinščak, M. (2007) Parameter Optimization in Voltage Pulse Plethysmography. U: IFMBE Proceedings.
@article{article, author = {Melin\v{s}\v{c}ak, Martina}, year = {2007}, pages = {198-201.}, keywords = {voltage pulse plethysmography, electrode tissue interface, tissue resistance variation}, title = {Parameter Optimization in Voltage Pulse Plethysmography}, keyword = {voltage pulse plethysmography, electrode tissue interface, tissue resistance variation}, publisherplace = {Ljubljana, Slovenija} }
@article{article, author = {Melin\v{s}\v{c}ak, Martina}, year = {2007}, pages = {198-201.}, keywords = {voltage pulse plethysmography, electrode tissue interface, tissue resistance variation}, title = {Parameter Optimization in Voltage Pulse Plethysmography}, keyword = {voltage pulse plethysmography, electrode tissue interface, tissue resistance variation}, publisherplace = {Ljubljana, Slovenija} }




Contrast
Increase Font
Decrease Font
Dyslexic Font