Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 307098

Modelling and simulation of the continuous power cable processing


Kosar, Vanja; Gomzi, Zoran; Šintić, Krešimir
Modelling and simulation of the continuous power cable processing // Chemical engineering and processing, 46 (2007), 2; 83-88 doi:10.1016/j.cep.2006.05.001 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 307098 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Modelling and simulation of the continuous power cable processing

Autori
Kosar, Vanja ; Gomzi, Zoran ; Šintić, Krešimir

Izvornik
Chemical engineering and processing (0255-2701) 46 (2007), 2; 83-88

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
power cable ; crosslinking ; PE-XL 4201 ; dicumyl peroxide ; mathematical model ; simulation

Sažetak
The production of medium-voltage power cables consists of two main stages: (1) heating and crosslinking reaction and (2) cable cooling. The crosslinking reaction takes place in the heated part of the vulcanization tube. The cable cooling is divided in two parts. First, part of the tube filled with cold water is cooled under high pressure. Second, the cable is cooled in the air before the end of the process. In this article, part of the process prior the cooling will be discussed. A numerical model was constructed by taking into account the heat transferred by conduction through the cable, as well as kinetics of the heat generated by cure reaction in the insulation. The shared contributions of the convection and radiation heat transfer through the pressured nitrogen were included in the heat transfer coefficient. The model was applied to a real plant production process. The calculated degree of crosslinking shows that uniformity through the insulation along radial axis at the end of the heated part of the vulcanization tube is the main requirement for the application of the product. The conversion reaches 99% as a result of the implemented real process parameters (line speed, temperature in the tube, nitrogen pressure) in the model.

Izvorni jezik
Engleski

Znanstvena područja
Kemijsko inženjerstvo



POVEZANOST RADA


Projekti:
MZOS-125-1251963-1974 - Analiza i modeliranje kemijskih reaktora (Tomašić, Vesna, MZOS ) ( CroRIS)

Ustanove:
Fakultet kemijskog inženjerstva i tehnologije, Zagreb

Profili:

Avatar Url Vanja Kosar (autor)

Avatar Url Zoran Gomzi (autor)

Poveznice na cjeloviti tekst rada:

doi dx.doi.org www.sciencedirect.com

Citiraj ovu publikaciju:

Kosar, Vanja; Gomzi, Zoran; Šintić, Krešimir
Modelling and simulation of the continuous power cable processing // Chemical engineering and processing, 46 (2007), 2; 83-88 doi:10.1016/j.cep.2006.05.001 (međunarodna recenzija, članak, znanstveni)
Kosar, V., Gomzi, Z. & Šintić, K. (2007) Modelling and simulation of the continuous power cable processing. Chemical engineering and processing, 46 (2), 83-88 doi:10.1016/j.cep.2006.05.001.
@article{article, author = {Kosar, Vanja and Gomzi, Zoran and \v{S}inti\'{c}, Kre\v{s}imir}, year = {2007}, pages = {83-88}, DOI = {10.1016/j.cep.2006.05.001}, keywords = {power cable, crosslinking, PE-XL 4201, dicumyl peroxide, mathematical model, simulation}, journal = {Chemical engineering and processing}, doi = {10.1016/j.cep.2006.05.001}, volume = {46}, number = {2}, issn = {0255-2701}, title = {Modelling and simulation of the continuous power cable processing}, keyword = {power cable, crosslinking, PE-XL 4201, dicumyl peroxide, mathematical model, simulation} }
@article{article, author = {Kosar, Vanja and Gomzi, Zoran and \v{S}inti\'{c}, Kre\v{s}imir}, year = {2007}, pages = {83-88}, DOI = {10.1016/j.cep.2006.05.001}, keywords = {power cable, crosslinking, PE-XL 4201, dicumyl peroxide, mathematical model, simulation}, journal = {Chemical engineering and processing}, doi = {10.1016/j.cep.2006.05.001}, volume = {46}, number = {2}, issn = {0255-2701}, title = {Modelling and simulation of the continuous power cable processing}, keyword = {power cable, crosslinking, PE-XL 4201, dicumyl peroxide, mathematical model, simulation} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Uključenost u ostale bibliografske baze podataka::


  • CA Search (Chemical Abstracts)


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font