Pregled bibliografske jedinice broj: 307063
Measuring Output Acoustic Power of an Ultrasonic Surgical System Using the Calorimetric Method
Measuring Output Acoustic Power of an Ultrasonic Surgical System Using the Calorimetric Method // 19th International congress on acoustics Official Publication / Calvo-Manzano, Antonio (ur.).
Madrid: Sociedad Espanola de Acustica, 2007. (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 307063 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Measuring Output Acoustic Power of an Ultrasonic Surgical System Using the Calorimetric Method
Autori
Petošić, Antonio ; Ivančević, Bojan ; Jambrošić, Kristian
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
19th International congress on acoustics Official Publication
/ Calvo-Manzano, Antonio - Madrid : Sociedad Espanola de Acustica, 2007
ISBN
84-87985-12-2
Skup
19th International congress on acoustics
Mjesto i datum
Madrid, Španjolska, 02.09.2007. - 07.09.2007
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
ultrasound; output power; calorimetric method; surgical device
Sažetak
Output radiated power of an ultrasonic processor system concentrating high power ultrasound energy in the sonotrode tip has been estimated using the calorimeter method. The tip of sonotrode is considered as a point source in linear and nonlinear working regime, depending on the applied electrical power. At the beginning, the input electrical impedance into electromechanical- acoustical system has been measured near the series resonance frequency when the tip of sonotrode was loaded (water) or unloaded (air), assuming linear behaviour of the system. Using equivalent circuits approach, the electroacoustical efficiency was calculated and the radiated acoustical power could be easily calculated knowing the applied electrical power. The output acoustical power has been measured using the calorimetric method where the tip of sonotrode was placed into several heat isolated boxes, and it was assumed that all radiated acoustical energy is converted into heat. The problem considering input electrical and radiated acoustical power in nonlinear working regime is that the waveforms of voltage and current are distorted and electroacoustical efficiency factor can’ t be easily calculated. Using the results of measurements, the correlation analysis between applied electrical power, temperature increase in the loading medium and radiated acoustical power has been done.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika
POVEZANOST RADA
Projekti:
036-1080231-1646 - Analiza i sinteza ultrazvučnog polja u svrhu aplikacije na tkivo (Ivančević, Bojan, MZO ) ( CroRIS)
Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb