Pregled bibliografske jedinice broj: 305627
Speciation of trace metals in natural waters: The influence of an adsorbed layer of natural organic matter (NOM) on voltammetric behaviour of copper
Speciation of trace metals in natural waters: The influence of an adsorbed layer of natural organic matter (NOM) on voltammetric behaviour of copper // Analytica chimica acta, 606 (2008), 1; 37-44 doi:10.1016/j.aca.2007.11.011 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 305627 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Speciation of trace metals in natural waters: The influence of an adsorbed layer of natural organic matter (NOM) on voltammetric behaviour of copper
Autori
Louis, Yoann ; Cmuk, Petra ; Omanović, Dario ; Garnier, Cédric ; Lenoble, Véronique ; Mounier, Stéphane ; Pižeta, Ivanka
Izvornik
Analytica chimica acta (0003-2670) 606
(2008), 1;
37-44
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
anodic stripping voltammetry ; metal complexing capacity ; organic matter ; pseudopolarography ; speciation ; trace metals
Sažetak
The influence of an adsorbed layer of the natural organic matter (NOM) on voltammetric behaviour of copper on a mercury drop electrode in natural water samples was studied. The adsorption of NOM strongly affects the differential pulse anodic stripping voltammogram (DPASV) of copper, leading to its distortion. Phase sensitive a.c. voltammetry confirmed that desorption of adsorbed NOM occurs in general at accumulation potentials more negative than -1.4 V. Accordingly, an application of negative potential (-1.6 V) for a very short time at the end of the accumulation time (1% of total accumulation time) to remove the adsorbed NOM was introduced in the measuring procedure. Using this protocol, a well resolved peak without interferences was obtained. It was shown that stripping chronopotentiogram of copper (SCP) in the depletive mode is influenced by the adsorbed layer in the same manner as DPASV. The influence of the adsorbed NOM on pseudopolarographic measurements of copper and on determination of copper complexing capacity (CuCC) was demonstrated. A shift of the peak potential and the change of the half-peak width on the accumulation potential (for pseudopolarography) and on copper concentration in solution (for CuCC) were observed. By applying a desorption step these effects vanished, yielding different final results.
Izvorni jezik
Engleski
Znanstvena područja
Geologija, Kemija
POVEZANOST RADA
Projekti:
098-0982934-2720 - Međudjelovanja oblika tragova metala u vodenom okolišu (Pižeta, Ivanka, MZOS ) ( CroRIS)
Ustanove:
Institut "Ruđer Bošković", Zagreb
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE
Uključenost u ostale bibliografske baze podataka::
- Chemical Abstracts