Pregled bibliografske jedinice broj: 301315
Roof tiles damages after 30 years in use
Roof tiles damages after 30 years in use // Proceedings of the 4th International Specialty Conference on The Conceptual Approach to Structural Design / Mola F ; Mola E ; Tan John S Y (ur.).
Singapur: CI-PREMIER PTE LTD, 2007. str. 637-643 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 301315 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Roof tiles damages after 30 years in use
Autori
Štirmer, Nina ; Jelčić, Marija ; Mikulić, Dunja ; Bjegović Dubravka
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of the 4th International Specialty Conference on The Conceptual Approach to Structural Design
/ Mola F ; Mola E ; Tan John S Y - Singapur : CI-PREMIER PTE LTD, 2007, 637-643
ISBN
978 -981-05-7586-1
Skup
4th International Specialty Conference on The Conceptual Approach to Structural Design
Mjesto i datum
Venecija, Italija, 27.06.2007. - 29.06.2007
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
roof tile; damage; soluble salts; frost damage; crack; spalling
Sažetak
Durability of clay roof tiles depends on different factors. Some damages of roof tiles are result of raw material composition and technology process, and some are result of different environmental conditions. A few decades ago, production process itself was not so sophisticated as nowadays. Typical damages of roof tiles can develop from soluble salts which result in appearance of stains, peeling and powder occurrence. This type of damages usually appears on lower side of roof tiles and can be very undesirable taking into consideration hygienic and aesthetic aspects. Likewise, lime grains from raw material can also cause damages like cracking and spalling. Moreover, one of the serious problems that can appear in roof tile is frost damage that depends on porosity and water absorbing capacity of roof tile. In the paper, typical damages of 30 years old roof tiles observed on several roof trusses are presented. From each site, a certain number of roof tiles were also taken for laboratory investigation. Laboratory testing was conducted to explore the various degradation mechanisms.
Izvorni jezik
Engleski
Znanstvena područja
Građevinarstvo, Temeljne tehničke znanosti
POVEZANOST RADA
Projekti:
082-0822161-2159 - RAZVOJ NOVIH MATERIJALA I SUSTAVA ZAŠTITE BETONSKIH KONSTRUKCIJA
082-0822161-2990 - Od nano do makrostrukture betona (Štirmer, Nina, MZOS ) ( CroRIS)
Ustanove:
Građevinski fakultet, Zagreb
Profili:
Marija Jelčić Rukavina
(autor)
Dunja Mikulić
(autor)
Nina Štirmer
(autor)
Dubravka Bjegović
(autor)