Comparison of river discharge measurements by conventional current meter and acoustic Doppler current profiler
Comparison of river discharge measurements by conventional current meter and acoustic Doppler current profiler // Zbornik radova Conference on Water Observation and Information System for Decision Support / Morell, Marc (ur.).
Ohrid: EC, IRD France, Ministry of environment and physical planning, Republic of Macedonia, 2004. (predavanje, nije recenziran, cjeloviti rad (in extenso), stručni)
CROSBI ID: 300218 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Comparison of river discharge measurements by conventional current meter and acoustic Doppler current profiler
(Usporedna mjerenja protoka rijeka primjenom hidrometrijskog krila i akustičkog Doppler mjerača protoka (ADCP))
Autori
Terek, Borivoj
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), stručni
Izvornik
Zbornik radova Conference on Water Observation and Information System for Decision Support
/ Morell, Marc - Ohrid : EC, IRD France, Ministry of environment and physical planning, Republic of Macedonia, 2004
ISBN
9989-110-26-3
Skup
BALWOIS - Conference on Water Observation and Information System for Decision Support
Mjesto i datum
Ohrid, Sjeverna Makedonija, 25.05.2004. - 29.05.2004
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Nije recenziran
Ključne riječi
River discharge; comparative measurements; ADCP; Croatia
Sažetak
The discharge measurements carried out on River Sava and River Mura by using both conventional current meter method and the ADCP are presented in the paper. The results of these measurements, the first of that kind carried out in Croatia, highlight comparative advantages of the ADCP measurement over current meter method. The ADCP discharge measurements were carried out by the DHMZ, while the current meter measurements were carried out by both DHMZ and HNVI. The discharge measured at the same stage using current meter and ADCP differ by the order of magnitude of 2%. Consistency of the discharges measured by ADCP was further confirmed by additional discharge measurements carried out on River Sava at slightly higher water level, where corresponding increase in measured discharge was recorded. The conducted measurements indicate that the ADCP used for measurements presents a significant advancement as regards the measurement accuracy, repeatability, duration, flexibility and operability.