Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 299641

Dangerous voltages due to direct lightning strike into the communication tower


Vujević, Slavko; Sarajčev, Petar
Dangerous voltages due to direct lightning strike into the communication tower // Journal of Communications Software and Systems (JCOMSS), 3 (2007), 1; 44-51 (podatak o recenziji nije dostupan, članak, znanstveni)


CROSBI ID: 299641 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Dangerous voltages due to direct lightning strike into the communication tower

Autori
Vujević, Slavko ; Sarajčev, Petar

Izvornik
Journal of Communications Software and Systems (JCOMSS) (1845-6421) 3 (2007), 1; 44-51

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
average potential method; ATP-EMTP; earthing grid; communication tower; lightning transient analysis; step and touch voltages

Sažetak
This paper presents a novel technique for computing dangerous voltages due to direct lightning strike into the communication tower and associated earthing system, which is based on the use of the well-known ATP-EMTP software package. The earthing grid and the communication tower structure are approximated by the circular cross section conductors. In numerical model, conductors are subdivided into segments (1D finite elements) and Clark's model with distributed constant parameters is then applied. Because of the limitations of ATP-EMTP software package, the leakage resistance of buried segments is modelled as additional lumped parameter. Analytical expressions for distributed and lumped segment parameters are derived using the average potential method. Mutual electromagnetic coupling between segments is neglected due to the limitations imposed by the ATP-EMTP software package, which is based on transmission line approach. Separate computer program is developed for obtaining the earth surface transient potential distribution, from which step and touch voltages are then computed.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Projekti:
0023015

Ustanove:
Fakultet elektrotehnike, strojarstva i brodogradnje, Split

Profili:

Avatar Url Petar Sarajčev (autor)

Avatar Url Slavko Vujević (autor)

Citiraj ovu publikaciju:

Vujević, Slavko; Sarajčev, Petar
Dangerous voltages due to direct lightning strike into the communication tower // Journal of Communications Software and Systems (JCOMSS), 3 (2007), 1; 44-51 (podatak o recenziji nije dostupan, članak, znanstveni)
Vujević, S. & Sarajčev, P. (2007) Dangerous voltages due to direct lightning strike into the communication tower. Journal of Communications Software and Systems (JCOMSS), 3 (1), 44-51.
@article{article, author = {Vujevi\'{c}, Slavko and Saraj\v{c}ev, Petar}, year = {2007}, pages = {44-51}, keywords = {average potential method, ATP-EMTP, earthing grid, communication tower, lightning transient analysis, step and touch voltages}, journal = {Journal of Communications Software and Systems (JCOMSS)}, volume = {3}, number = {1}, issn = {1845-6421}, title = {Dangerous voltages due to direct lightning strike into the communication tower}, keyword = {average potential method, ATP-EMTP, earthing grid, communication tower, lightning transient analysis, step and touch voltages} }
@article{article, author = {Vujevi\'{c}, Slavko and Saraj\v{c}ev, Petar}, year = {2007}, pages = {44-51}, keywords = {average potential method, ATP-EMTP, earthing grid, communication tower, lightning transient analysis, step and touch voltages}, journal = {Journal of Communications Software and Systems (JCOMSS)}, volume = {3}, number = {1}, issn = {1845-6421}, title = {Dangerous voltages due to direct lightning strike into the communication tower}, keyword = {average potential method, ATP-EMTP, earthing grid, communication tower, lightning transient analysis, step and touch voltages} }




Contrast
Increase Font
Decrease Font
Dyslexic Font