Pregled bibliografske jedinice broj: 297706
Differential surface plasmon resonance imaging for high-throughput bioanalyses
Differential surface plasmon resonance imaging for high-throughput bioanalyses // Analytical Chemistry, 79 (2007), 2; 702-709 doi:10.1021/ac061623j (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 297706 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Differential surface plasmon resonance imaging for high-throughput bioanalyses
Autori
Boecker, Daniel ; Zybin, Alexander ; Horvatić, Vlasta ; Grunwald, Christian ; Niemax, Kay
Izvornik
Analytical Chemistry (0003-2700) 79
(2007), 2;
702-709
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
surface plasmon resonance; imaging; bio-analyses
Sažetak
A new imaging technique for high-throughput surface plasmon resonance (SPR) measurements is described. It is the application of a CCD camera for simultaneous processing of two images at two different wavelengths provided by two laser diodes. The two lasers are brought to resonance by tuning of the angle of incidence so that the detection power and the dynamic range are optimized for the wavelength pair selected. Applying a special differential processing of the two images, SPR measurements can be performed near the shot noise limit taking into account the number of CCD pixels involved. It is shown that the detection limit of imaging methods can be improved significantly if the working point is set near to the reflection minimum instead of choosing the angle with the steepest slope of the reflection curve. The technique is demonstrated by simultaneous measurement of hybridization reactions of three different types of thiolated oligonucleotides in 30 small areas set by a commercial spotter. A noise level of 1.5 x 10-6 refractive index units (RIU) was obtained for single, 500 x 500 micron2 reaction areas. The noise level was about 6 x 10-7 RIU when five areas were taken into account. The present arrangement and the particular spotter applied would allow smultaneous measurements of up to 400 binding reactions with a noise level of about 1.5 x 10-6 RIU.
Izvorni jezik
Engleski
Znanstvena područja
Fizika
POVEZANOST RADA
Projekti:
035-0352851-2853 - Spektroskopija Rydbergovih atoma i molekula (Horvatić, Vlasta, MZOS ) ( CroRIS)
Ustanove:
Institut za fiziku, Zagreb
Profili:
Vlasta Horvatić
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE