Pregled bibliografske jedinice broj: 293600
Beam test results of a Shashlik calorimeter in a high magnetic field
Beam test results of a Shashlik calorimeter in a high magnetic field // Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 376 (1996), 3; 361-367 doi:10.1016/0168-9002(96)00416-0 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 293600 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Beam test results of a Shashlik calorimeter in a high
magnetic field
Autori
Aspell, P. ; Bates, S. ; Bloch, Ph. ; Grabit, R. ; Jarron, P. ; Kloukinas, K. ; Lemeilleur, F. ; Loos, R. ; Marchioroa, A. ; Rosso, E. ; Badier, J. ; Bruel, Ph. ; Busata, A. ; Busson, Ph. ; Charlot, C. ; Dorchies, F. ; Dobrzynski, L. ; Ferreira, O. ; Gregory, Ch. ; Karar, A. ; Manigot, P. ; Tanaka, R. ; Vane1, J.Ch. ; Bityukov, S. ; Obraztsov, V. ; Ostankov, A. ; Protopopov, Yu. ; Rykalin, V. ; Spiridonov, P. ; Soushkov, V. ; Vasilchenko, V. ; Clayton, E. ; Miller, D. ; Seez, C. ; Virdee, T.S. ; Djilkibaev, R. ; Gninenko, S. ; Guschin, E. ; Musienko, Y. ; Popov, V. ; Skasyrskaya, A. ; Semenyuk, I. ; Cheremukhin, I. ; Egorov, A. ; Golutvin, I. ; Kozlov, Y. ; Moissenz, P. ; Sergueev, S. ; Sidorov, A. ; Zubarev, E. ; Zamiatin, N. ; Bordalo, P. ; Ramos, S. ; Varela, J. ; Cockerill, D.J.A. ; Connolly, J. ; Denton, L. ; Godinović, Nikola ; Puljak, Ivica ; Sorić, Ivica ; Chendvankar, S.R. ; Gupta, S.K. ; Ganguli, S.N. ; Gurtu, A. ; Maity, M. ; Majumder, G. ; Mazumdar, K ; Moulik, T.
Izvornik
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (0168-9002) 376
(1996), 3;
361-367
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
CMS ; electromagnetic calorimeter ; preshower
Sažetak
Shashlik calorimeter prototypes equipped with preshower detector have been tested in 3 T magnetic field with electron beam at CERN-SPS. The signal from electrons increases as much as 11% at 3 T magnetic field. No significant deterioration on the energy resolution as well as the preshower detector performance have been observed.
Izvorni jezik
Engleski
Znanstvena područja
Fizika
POVEZANOST RADA
Ustanove:
Fakultet elektrotehnike, strojarstva i brodogradnje, Split
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus