Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 27794

Plethysmorgaphy Measurements using Short Current Pulses with Low-Duty Cycle


Šantić, Ante; Štritof, Tomislav; Bilas, Vedran
Plethysmorgaphy Measurements using Short Current Pulses with Low-Duty Cycle // Proceedings of the 20th Annual International Conference of the IEEE EMBS, Volume 20, Biomedical Engineering Towards The Year 2000 and Beyond / Chang, H.K. ; Zhang, Y.T. (ur.).
Hong Kong: IEEE EMBS, 1998. str. 1889-1892 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 27794 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Plethysmorgaphy Measurements using Short Current Pulses with Low-Duty Cycle

Autori
Šantić, Ante ; Štritof, Tomislav ; Bilas, Vedran

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Proceedings of the 20th Annual International Conference of the IEEE EMBS, Volume 20, Biomedical Engineering Towards The Year 2000 and Beyond / Chang, H.K. ; Zhang, Y.T. - Hong Kong : IEEE EMBS, 1998, 1889-1892

Skup
20th Annual International Conference of the IEEE EMBS

Mjesto i datum
Hong Kong, Kina, 29.10.1998. - 01.11.1998

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
short current pulses plethysmorgaphy

Sažetak
Pulse plethysmography with very low-duty cycle offers much lower current load of examined bio-tissue in comparison to sine-wave impedance plethysmography. This enables application of strong current pulses with the same bio-tissue loading effect as for impedance plethysmography, resulting in larger signal and better signal to noise ratio. Determination of an equivalent electrical circuit of electrodes connected with bio-tissue is possible by fitting the measured waveshape with a resistor and capacitor connected in series, or better with three or four elements. A simplified block diagram of the pulse plethysmograph is given as well. Blood pressure wave-shape obtained on arteries and volume changes during respiration are measured and shown.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Projekti:
036026

Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb

Profili:

Avatar Url Ante Šantić (autor)

Avatar Url Tomislav Štritof (autor)

Avatar Url Vedran Bilas (autor)


Citiraj ovu publikaciju:

Šantić, Ante; Štritof, Tomislav; Bilas, Vedran
Plethysmorgaphy Measurements using Short Current Pulses with Low-Duty Cycle // Proceedings of the 20th Annual International Conference of the IEEE EMBS, Volume 20, Biomedical Engineering Towards The Year 2000 and Beyond / Chang, H.K. ; Zhang, Y.T. (ur.).
Hong Kong: IEEE EMBS, 1998. str. 1889-1892 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Šantić, A., Štritof, T. & Bilas, V. (1998) Plethysmorgaphy Measurements using Short Current Pulses with Low-Duty Cycle. U: Chang, H. & Zhang, Y. (ur.)Proceedings of the 20th Annual International Conference of the IEEE EMBS, Volume 20, Biomedical Engineering Towards The Year 2000 and Beyond.
@article{article, author = {\v{S}anti\'{c}, Ante and \v{S}tritof, Tomislav and Bilas, Vedran}, year = {1998}, pages = {1889-1892}, keywords = {short current pulses plethysmorgaphy}, title = {Plethysmorgaphy Measurements using Short Current Pulses with Low-Duty Cycle}, keyword = {short current pulses plethysmorgaphy}, publisher = {IEEE EMBS}, publisherplace = {Hong Kong, Kina} }
@article{article, author = {\v{S}anti\'{c}, Ante and \v{S}tritof, Tomislav and Bilas, Vedran}, year = {1998}, pages = {1889-1892}, keywords = {short current pulses plethysmorgaphy}, title = {Plethysmorgaphy Measurements using Short Current Pulses with Low-Duty Cycle}, keyword = {short current pulses plethysmorgaphy}, publisher = {IEEE EMBS}, publisherplace = {Hong Kong, Kina} }




Contrast
Increase Font
Decrease Font
Dyslexic Font