Pregled bibliografske jedinice broj: 2730
Small angle scattering of synchrotron light on nanophase TiO_2 measured at ELETTRA
Small angle scattering of synchrotron light on nanophase TiO_2 measured at ELETTRA // 6th Croatian-Slovenian crystallographic meeting, Abstracts / Kamenar, Boris ; Golič, Ljubo (ur.).
Zagreb: Hrvatska kristalografska unija, 1997. str. 58-58 (predavanje, međunarodna recenzija, sažetak, znanstveni)
CROSBI ID: 2730 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Small angle scattering of synchrotron light on nanophase TiO_2 measured at ELETTRA
Autori
Lučić-Lavčević, Magdy ; Dubček, Pavo ; Milat, Ognjen ; Etlinger, Božidar ; Turković, Alekksandra ; Amenitch, Heinz
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
6th Croatian-Slovenian crystallographic meeting, Abstracts
/ Kamenar, Boris ; Golič, Ljubo - Zagreb : Hrvatska kristalografska unija, 1997, 58-58
Skup
6th Croatian-Slovenian crystallographic meeting
Mjesto i datum
Umag, Hrvatska, 19.06.1997. - 21.06.1997
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
nanophase; thin films; TiO_2; synchrotron light
Sažetak
Dye- sensitized cells differ from the conventional semiconductor devices in that they separate the function of light absorption from charge carrier transport. The device is based on a 10 microns thick, optically transparent film of titanium dioxide particles a few nanometers in size, coated with a monolayre of charge-transfer dye to sesitize film for light harvesting. In our previous studies some properties of nanophase TiO_2 obtained by sol-gel method have been measured by Raman spectrometry, X-ray diffraction, high resolution electron microscopy and small angle X-ray scattering (SAXS). Grain sizes and distributions obtained by all four methods agree and vary between 5 and 12 nm. In order to determine the void volume and pores distribution in our TiO_2 samples, prepared by four different methods: spay, chemical vapor deposition (CVD), sol-gel and from commercial P25, we have performed SAXS measurements using synchrotron radiation at ELETTRA, Trieste, which has 1000 times higher intensity than X-ray tube of our set-up in Zagreb. The first results of these measurements are presented in this work.
Izvorni jezik
Engleski
Znanstvena područja
Fizika, Kemijsko inženjerstvo
POVEZANOST RADA
Ustanove:
Kemijsko-tehnološki fakultet, Split,
Institut "Ruđer Bošković", Zagreb
Profili:
Magdy Lučić-Lavčević
(autor)
Ognjen Milat
(autor)
Božidar Etlinger
(autor)
Pavo Dubček
(autor)